ISE Electrode
HI4013-51 Nitrate Module for Half-Cell ISE (1 pc.)
The HI4013-53 is a single replacement sensing module for the HI4013 nitrate half-cell ion selective electrode.
• Nitrate-sensitive polymer
• Durable PVC matrix
• Easy to replace
Nitrate Module for Half-Cell ISE (3 pcs)
The HI4013-53 is a set of 3 replacement sensing modules for the HI4013 nitrate half-cell ion selective electrode.
• Nitrate-sensitive polymer
• Durable PVC matrix
• Easy to replace
Nitrate Combination Ion Selective Electrode (ISE)
The HI4113 is a liquid membrane, combination ion selective electrode (ISE) for the determination of nitrate (NO3-) in solution. The PVC membrane comprised with organic ion exchanger produces a potential change due to the nitrate ion exchange between the organic polymer membrane and the sample. The internal sensing elements are housed within a durable polyetherimide (PEI) body.
The HI4113 is ideal for a variety of applications in the food industry, agriculture, and water analysis.
• Liquid membrane sensor
• Skirted cone geometry
• Detection from 0.62 to 6, 200 mg/L NO3-
Nitrate Module for Combination ISE (3 pcs)
The HI4113-53 contains three replacement sensing modules for the nitrate combination ion selective electrode.
• Nitrate-sensitive polymer
• Durable PVC matrix
• Easy to replace
Potassium Half-Cell Ion-Selective Electrode (ISE)
The HI4014 is a liquid membrane, half-cell ion selective electrode (ISE) for the determination of potassium (K+) in solution. The PVC membrane comprised with organic ion exchanger produces a potential change due to the potassium ion exchange between the organic polymer membrane and the sample. The internal sensing elements are housed within a durable epoxy body.
The HI4014 is ideal for a variety of applications in wine, agriculture, and water analysis.
• Liquid membrane sensor
• Detection from 0.039 to 39, 100 mg/L K+
• For use with HI5315 reference half-cell
Ionic Strength Adjuster (ISA) for Potassium ISEs
HI4014-00 is a 500 mL bottle of ionic strength adjuster (ISA) solution for use with potassium ion selective electrodes.
Hanna ISA solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna's line of solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
Required for potassium measurements
Air tight bottle with tamper-proof seal
Clearly marked lot number and expiration date
Potassium ISE 0.1M Standard
HI4014-01 is a 500 mL bottle of premium quality 0.1M potassium standard solution.
Hanna ISE standards have the lot number and expiration date clearly marked on the label. Bottles are air tight with a tamper-proof seal to ensure the quality of the standard solution. Hanna’s line of standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
• 0.1M potassium standard
• Air tight bottle with tamper-proof seal
• Lot number and expiration date printed on each label
Potassium Module for Half-Cell ISE
The HI4014-51 is a replacement sensing module for the potassium half-cell ion selective electrode.
• Potassium-sensitive polymer
• Durable PVC matrix
• Easy to replace
Potassium Combination Ion-Selective Electrode (ISE)
The HI4114 is a liquid membrane, combination ion selective electrode (ISE) for the determination of potassium (K+) in solution. The PVC membrane comprised with organic ion exchanger produces a potential change due to the potassium ion exchange between the organic polymer membrane and the sample. The internal sensing elements are housed within a durable polyetherimide (PEI) body.
The HI4114 is ideal for a variety of applications in wine, agriculture, and water analysis.
• Liquid membrane sensor
• Skirted cone geometry
• Detection from 0.039 to 39, 100 mg/L K+
Potassium Module for Combination ISE
The HI4114-51 is a replacement sensing module for the HI4114 potassium combination ion selective electrode.
Potassium-sensitive polymer
Durable PVC matrix
Easy to replace
Glass Body General Purpose Reference Electrode
The HI5311 is a glass body, refillable, double junction, half-cell reference electrode with a 4 mm banana connector. This electrode has a single ceramic junction in the outer reference cell and is made for use in temperatures ranging from -5 to 100℃.
This design consideration is made for general purpose use with pH, ORP, or ion selective electrode half-cells, as well as for use in a variety of titrations.
• Half-Cell Design
• Refillable Electrode
• Double Junction Reference
Reference Electrode for Samples with Suspended Solids
The HI5312 is a glass body, refillable, double junction, half-cell reference electrode with a 4 mm banana connector. This electrode has a PTFE sleeve junction in the outer reference cell and is made for use in temperatures ranging from -5 to 80℃.
This design consideration is made for measurements in samples with suspended solids, and can also be used in a variety of titrations.
• Half-Cell Design
• Refillable Electrode
• PTFE Sleeve Junction
PEI Body Reference Electrode for FC301B
The HI5313 is a PEI body, refillable, single junction, half-cell reference electrode with a 4 mm banana connector. This electrode has a single ceramic junction in the outer reference cell and is made for use in temperatures ranging from -5 to 60℃.
This design consideration is made for use with the FC301B fluoride half-cell ion selective electrode.
• Half-Cell Design
• Durable PEI Body
• Gel Electrolyte
Glass Body Reference Electrode for Measurements with Remote Filling
The HI5314 is a glass body, refillable, double junction, half-cell reference electrode with a 4 mm banana connector. This electrode has a double ceramic junction in the outer reference cell and a side arm construction.
This design consideration is made for use in applications that require remote filling in temperatures ranging from -5 to 100℃.
• Refillable Electrode
• Double Ceramic Junction
• Side Arm Construction
Reference Electrode for ISE Half-Cells
The HI5315 reference electrode is a silver/silver chloride double junction half-cell designed for use with ion selective electrode (ISE) and pH half-cells.
The reference electrode provides a stable reference voltage when paired with a sensing half-cell. The external reference electrolyte chamber is refillable and easy to drain with the quick flush sleeve design. The internal reference elements are housed within a durable polyetherimide (PEI) body. A fast responding liquid junction, excellent reproducibility, and ease of use will mark this reference as the “best” in your lab.