Turbidity
Calibration Standards for Haze Meter - HI847492-11
The HI847492-11 Calibration Standards provide a simple solution to calibrating and validating the HI847492 Haze Meter for Beer Quality Analysis. Hanna turbidity calibration standards are prepared from NIST traceable primary standard reference materials and come supplied with a certificate of analysis. The certificate of analysis provides the lot number, reference values, and expiration date for traceability when certifying the appropriate turbidity meter.
• Supplied with Certificate of Analysis
• Standard values of <0.1, 15, 100, and 800 FTU
• Reusable with long shelf-life stability
Turbidity Calibration Standards - HI88703-11
The HI88703-11 Turbidity Calibration Standards provide a simple solution to calibrating and validating turbidity meters that have a 0 to 4000 NTU range. Hanna turbidity calibration standards are prepared from NIST traceable primary standard reference materials and come supplied with a certificate of analysis. The certificate of analysis provides the lot number, reference values, and expiration date for traceability when certifying the appropriate turbidity meter.
• Supplied with Certificate of Analysis
• Standard values of <0.10, 15.0, 100, 750, and 2000 NTU
• Reusable with long shelf life stability
Turbidity Calibration Standards - HI88713-11
The HI88713-11 Turbidity Calibration Standards provide a simple solution to calibrating and validating turbidity meters that have a 0 to 1000 FNU range and 0.00 to 4000 NTU range. Hanna turbidity calibration standards are prepared from NIST traceable primary standard reference materials and come supplied with a certificate of analysis. The certificate of analysis provides the lot number, reference values, and expiration date for traceability when certifying the appropriate turbidity meter.
• Supplied with Certificate of Analysis
• Standard values of <0.10, 15, 100, 750 FNU, and 2000 NTU
• Reusable with long shelf life stability
Free and Total Chlorine CAL Check™ Standards - HI93414-11
The HI93414-11 Free and Total Chlorine CAL Check™ Standards provide a simple solution to calibrating and validating compatible benchtop and portable photometers. This high quality set of standards is manufactured in our state-of-the-art facility and comes supplied with a certificate of analysis. The certificate of analysis provides the lot number, reference values, and expiration date for traceability when certifying compatible free and total chlorine photometers.
• Supplied with Certificate of Analysis
• Standard value of 1.00 ±0.03 mg/L chlorine @ 25℃
• Reusable with long shelf life stability
HI98703-58 Silicone Oil (15 mL)
HI98703-58 silicone oil is for use with Hanna’s line of turbidity meters. This easy to use dropper bottle ensures the glass cuvette used for turbidimetric measurements remains free from imperfections and scratches, helping to provide accurate readings every time.
• Convenient dropper bottle
• Marked with lot number and expiration date
• Light tight bottle
Turbidity Calibration Standards for HI98713 - HI98713-11
The HI98713-11 Turbidity Calibration Standards provide a simple solution to calibrating and validating turbidity meters that have a 0 to 1000 FNU range. Hanna turbidity calibration standards are prepared from NIST traceable primary standard reference materials and come supplied with a certificate of analysis. The certificate of analysis provides the lot number, reference values, and expiration date for traceability when certifying the appropriate turbidity meter.
• Supplied with Certificate of Analysis
• Standard values of <0.1, 15, 100, and 750 FNU
• Reusable with long shelf life stability
Turbidity Calibration Standards - HI98703-11
The HI98703-11 Turbidity Calibration Standards provide a simple solution to calibrating and validating turbidity meters that have a 0 to 1000 NTU range. Hanna turbidity calibration standards are prepared from NIST traceable primary standard reference materials and come supplied with a certificate of analysis. The certificate of analysis provides the lot number, reference values, and expiration date for traceability when certifying the appropriate turbidity meter.