Fluoride
Fluoride Half-Cell Ion Selective Electrode (ISE) - FC301B
The FC301B is a solid state, half-cell ion selective electrode (ISE) for the determination of fluoride (F-) in solution. The lanthanum fluoride crystal membrane produces a potential change due to the fluoride ion exchange between the membrane and the sample. The internal sensing elements are housed within a durable epoxy body. The FC301B is ideal for a variety of applications in drinking water treatment, environmental monitoring, and plating baths.
• Solid state sensor
• Detection from 0.02 mg/L to saturated F-
• For use with HI5315 reference half-cell
Fluoride Half-Cell Ion-Selective Electrode (ISE)
The HI4010 is a solid state, half-cell ion selective electrode (ISE) for the determination of fluoride (F-) in solution. The lanthanum fluoride crystal membrane produces a potential change due to the fluoride ion exchange between the membrane and the sample. The internal sensing elements are housed within a durable epoxy body.
The HI4010 is ideal for a variety of applications in drinking water treatment, environmental monitoring, and plating baths.
• Solid state sensor
• Detection from 0.02 mg/L to saturated F-
• For use with HI5315 reference half-cell
TISAB II for Fluoride ISEs (500 mL)
HI4010-00 is a 500 mL bottle of TISAB II solution for use with fluoride ion selective electrodes.
Hanna ISA solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
• Required for fluoride measurements
• Air tight bottle with tamper-proof seal
• Clearly marked lot number and expiration date
Fluoride ISE 0.1M Standard 0.1M
HI4010-01 is a 500 mL bottle of premium quality 0.1M fluoride standard solution.
Hanna ISE standards have the lot number and expiration date clearly marked on the label. Bottles are air tight with a tamper-proof seal to ensure the quality of the standard solution. Hanna's line of standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
0.1M fluoride standard
Air tight bottle with tamper-proof seal
Lot number and expiration date printed on each label
Fluoride ISE 100 ppm Standard
HI4010-02 is a 500 mL premium quality 100 mg/L (ppm) fluoride standard solution.
Hanna ISE standards have the lot number and expiration date clearly marked on the label. Bottles are air tight with a tamper-proof seal to ensure the quality of the standard solution. Hanna’s line of standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
• 100 ppm (mg/L) fluoride standard
• Air tight bottle with tamper-proof seal
• Lot number and expiration date printed on each label
Fluoride ISE 1000 ppm Standard
HI4010-03 is a 500 mL bottle of premium quality 1000 ppm (mg/L) fluoride standard solution.
Hanna ISE standards have the lot number and expiration date clearly marked on the label. Bottles are air tight with a tamper-proof seal to ensure the quality of the standard solution. Hanna’s line of standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
• 1000 ppm (mg/L) fluoride standard
• Air tight bottle with tamper-proof seal
• Lot number and expiration date printed on each label
TISAB II for Fluoride ISEs (1 gallon)
HI4010-05 is a 1 gallon bottle of TISAB II solution for use with fluoride ion selective electrodes.
Hanna ISA solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
• Required for fluoride measurements
• Air tight bottle with tamper-proof seal
• Clearly marked lot number and expiration date
TISAB III Concentrate for Fluoride ISEs
HI4010-06 is a 500 mL bottle of TISAB III concentrate solution is for use with fluoride ion selective electrodes.
Hanna ISA solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
• Required for fluoride measurements
• Air tight bottle with tamper-proof seal
• Clearly marked lot number and expiration date
Fluoride ISE 10 ppm Standard with TISAB II
HI4010-10 is a 500 mL bottle of premium quality 10 ppm (mg/L) fluoride standard solution that is premixed with TISAB II ionic strength adjuster.
Hanna ISE standards have the lot number and expiration date clearly marked on the label. Bottles are air tight with a tamper-proof seal to ensure the quality of the standard solution. Hanna’s line of standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
• 10 ppm (mg/L) fluoride standard with TISAB II
• Air tight bottle with tamper-proof seal
• Lot number and expiration date printed on each label
Fluoride ISE 1 ppm Standard with TISAB II
HI4010-11 is a 500 mL bottle of premium quality 1 ppm (mg/L) fluoride standard solution that is premixed with TISAB II ionic strength adjuster.
Hanna ISE standards have the lot number and expiration date clearly marked on the label. Bottles are air tight with a tamper-proof seal to ensure the quality of the standard solution. Hanna’s line of standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
• 1 ppm (mg/L) fluoride standard with TISAB II
• Air tight bottle with tamper-proof seal
• Lot number and expiration date printed on each label
Fluoride ISE 2 ppm Standard with TISAB II
HI4010-12 is a 500 mL bottle of premium quality 2 ppm (mg/L) fluoride standard solution that is premixed with TISAB II ionic strength adjuster.
Hanna ISE standards have the lot number and expiration date clearly marked on the label. Bottles are air tight with a tamper-proof seal to ensure the quality of the standard solution. Hanna’s line of standards have been specially formulated to have an shelf life of 5 years from the date of manufacture for an unopened bottle.
• 2 ppm (mg/L) fluoride standard with TISAB II
• Air tight bottle with tamper-proof seal
• Lot number and expiration date printed on each label
Fluoride Calibration Solution Kit
HI4010-30 is a set of premium quality solutions for the fluoride ion selective electrode. The kit contains four 500 mL bottles each of 1 ppm (mg/L) fluoride standard with TISAB II, 10 ppm (mg/L) fluoride standard with TISAB II, and TISAB II ionic strength adjuster.
Hanna ISE solutions have the lot number and expiration date clearly marked on the label. Bottles are air tight with a tamper-proof seal to ensure the quality of the standard solution. Hanna’s line of standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
• Two fluoride standards and ISA solution
• Air tight bottles with tamper-proof seal
• Lot number and expiration date printed on each label
Fluoride Combination Ion-Selective Electrode (ISE)
The HI4110 is a solid state, combination ion-selective electrode (ISE) for the determination of fluoride (F-) in solution. The lanthanum fluoride crystal membrane produces a potential change due to the fluoride ion exchange between the membrane and the sample. The internal sensing elements are housed within a durable body, composed of a mixture of polyetherimide (PEI) and epoxy.
The HI4110 is ideal for a variety of applications in drinking water treatment, environmental monitoring, and plating baths.
• Solid state sensor
• Skirted cone geometry
• Detection from 0.02 mg/L to saturated F-
Fluoride Module for Combination ISE
The HI4110-51 is a replacement sensing module for the HI4110 fluoride combination ion selective electrode.