Automatic Titration
Automatic Potentiometric Titrator - HI931
The HI931 Automatic Titrator is the answer to your dedicated titration needs. Fully customizable, the HI931 delivers accurate results and intuitive user experience, all in a compact package. Titrate for a variety of measurements at the push of a button including acids, bases, redox, and selective ions. No additional programming upgrades to purchase. The only things you need to start using the HI931 are a sensor and titrant.
• Small footprint so you can fully optimize your benchtop.
• Unmatched 40, 000-step dosing pump for small volumes of titrant to help you achieve a very precise endpoint for greater consistency.
• Flexibility to store up to 100 methods.
Photometric Probe for Colorimetric Titrations at 470 nm - HI900604
For many titrations, a potentiometric determination of the equivalence point is simply not possible. However, manually performing complexometric titrations can be inaccurate due to ambiguous color changes and when using non-aqueous or semi-opaque liquids, such as lubricating oils. In these cases, the use of a photometric probe for the optical determination of an endpoint during volumetric analysis is preferred. Hanna Instruments introduces HI900604 photometric electrode for when a color change is still the best solution.
• High color sensitivity in a compact design
• Chemically resistant glass-body construction
• Stable blue LED (470 nm) light source with low drift
Photometric Probe for Colorimetric Titrations at 625 nm - HI900602
For many titrations, a potentiometric determination of the equivalence point is simply not possible. However, manually performing complexometric titrations can be inaccurate due to ambiguous color changes and when using non-aqueous or semi-opaque liquids, such as lubricating oils. In these cases, the use of a photometric probe for the optical determination of an endpoint during volumetric analysis is preferred. Hanna Instruments introduces HI900602 photometric electrode for when a color change is still the best solution.
• High color sensitivity in a compact design
• Chemically resistant glass-body construction
• Stable red LED (625 nm) light source with low drift
Photometric Probe for Colorimetric Titrations at 525 nm - HI900601
For many titrations, a potentiometric determination of the equivalence point is simply not possible. However, manually performing complexometric titrations can be inaccurate due to ambiguous color changes and when using non-aqueous or semi-opaque liquids, such as lubricating oils. In these cases, the use of a photometric probe for the optical determination of an endpoint during volumetric analysis is preferred. Hanna Instruments introduces HI900601 photometric electrode for when a color change is still the best solution.
• High color sensitivity in a compact design
• Chemically resistant glass-body construction
• Stable green LED (525 nm) light source with low drift
Photometric Probe for Colorimetric Titrations at 590 nm - HI900603
For many titrations, a potentiometric determination of the equivalence point is simply not possible. However, manually performing complexometric titrations can be inaccurate due to ambiguous color changes and when using non-aqueous or semi-opaque liquids, such as lubricating oils. In these cases, the use of a photometric probe for the optical determination of an endpoint during volumetric analysis is preferred. Hanna Instruments introduces HI900603 photometric electrode for when a color change is still the best solution.
• High color sensitivity in a compact design
• Chemically resistant glass-body construction
• Stable yellow LED (590 nm) light source with low drift
Volumetric Karl Fischer Titrator - HI933
For scientists and professionals who need exact water content determination from 0.01 to 100%, our new generation of the Volumetric Karl Fischer Titrator is engineered to meet or exceed your technical requirements while delivering a lower cost of ownership. With cutting-edge features packed into a compact design, this titrator delivers accurate results and requires less space in the lab. Get accurate water content determination at the push of a button. Designed for the modern lab, this karl fischer titrator is the perfect fit for your testing environment.
• Compact design will save space in the lab without compromising your results.
• Durable heat and chemical resistant body.
• Sealed solvent system helps to keep water out of the system, while giving you minimal exposure to the reagents.
Coulometric Karl Fischer Titrator - HI934-Without diaphragm
For scientists and professionals who need exact water content determination from 1 ppm to 5%, our new generation of the Coulometric Karl Fischer Titrator is engineered to meet or exceed your technical requirements while delivering a lower cost of ownership. With cutting-edge features packed into a compact design, this titrator delivers accurate results and requires less space in the lab. Get accurate water content determination at the push of a button. Designed for the modern lab, this karl fischer titrator is the perfect fit for your testing environment.
• Compact design will save space in the lab without compromising your results.
• Durable heat and chemical resistant body.
• Sealed solvent system helps to keep water out of the system, while giving you minimal exposure to the reagents.
Coulometric Karl Fischer Titrator - HI934-with diaphragm
For scientists and professionals who need exact water content determination from 1 ppm to 5%, our new generation of the Coulometric Karl Fischer Titrator is engineered to meet or exceed your technical requirements while delivering a lower cost of ownership. With cutting-edge features packed into a compact design, this titrator delivers accurate results and requires less space in the lab. Get accurate water content determination at the push of a button. Designed for the modern lab, this karl fischer titrator is the perfect fit for your testing environment.
• Compact design will save space in the lab without compromising your results.
• Durable heat and chemical resistant body.
• Sealed solvent system helps to keep water out of the system, while giving you minimal exposure to the reagents.
Mini Titrator for Measuring Sulfur Dioxide in Wine - HI84500
The HI84500 is a simple, fast, and affordable automatic mini titrator designed for testing free or total sulfur dioxide (SO2) levels in wine. Based on the Ripper Method, this mini titrator uses an optimized, preprogrammed method of analysis with a powerful algorithm that determines the completion of the titration reaction by the use of a specialized ORP electrode.
The HI84500 incorporates a precision piston style dosing pump that adjusts the volume of dosing dynamically based on the voltage changed. This dosing system reduces the amount of time required for the titration while providing for a highly accurate determination of the amount of titrant used.
This mini titrator is supplied complete with all the materials necessary to perform low and high range measurement of SO2. All chemicals are premixed and prepackaged including standardized titrants, reagents and pump calibration solution. There is no need for volumetric glassware or analytical balances.
• Piston driven pump for accurate dynamic dosing
• Complete with ORP electrode with CPS™ Technology
• Pre-standardized titrant and pre-measured reagents
Mini-Titrator for Measuring Titratable Acidity in Wine - HI84502
The HI84502 is a simple, fast, and affordable automatic mini titrator designed for testing total acidity levels in wine. Based on an acid-base titration method, this mini titrator uses an optimized preprogrammed method of analysis with a powerful algorithm that determines the completion of the titration reaction by the use of a specialized wine pH electrode.
Analysis for titratable acidity with the HI84502 is not selective for acids of similar strength. In this method, a base of known concentration is used to understand the overall acid content of a sample and express it as the main acid present in wine, tartaric acid.
The HI84502 incorporates a precision piston style dosing pump that adjusts the volume of dosing dynamically based on the voltage changed. This dosing system reduces the amount of time required for the titration while providing for a highly accurate determination of the amount of titrant used.
This mini titrator is supplied complete with all the materials necessary to perform low and high range measurements of total acidity. All chemicals are premixed and prepackaged including standardized titrants, reagents and pump calibration solution. There is no need for volumetric glassware or analytical balances.
• Piston driven pump for accurate dynamic dosing
• Complete with pH electrode with CPS™ Technology
• Pre-standardized titrant and pre-measured reagents
Mini Titrator for Measuring Titratable Acidity in Fruit Juice - HI84532
The HI84532 is a simple, fast, and affordable automatic mini titrator designed for testing the acidity of fruit juice. Based on an acid base titration method, this mini titrator uses an optimized preprogrammed method of analysis with a powerful algorithm that determines the completion of the titration reaction by the use of a glass body pH electrode.
The HI84532 incorporates a precision piston style dosing pump that adjusts the volume of titrant dosed dynamically based on a voltage change. This dosing system reduces the amount of time required for the titration while providing for a highly accurate determination of the amount of titrant used.
This mini titrator is supplied complete with all the materials necessary to perform low and high range measurements of titratable acidity in fruit juice. Results are displayed as % citric acid, tartaric acid and malic acid. All chemicals are premixed and prepackaged including standardized titrants, reagents and pump calibration solution. There is no need for volumetric glassware or analytical balances making titrations fast and easy to perform.
• Piston driven pump for accurate dynamic dosing
• Complete with glass double junction pH electrode
• Pre-standardized titrant and pre-measured reagents
Mini Titrator for Measuring Titratable Alkalinity in Water and Wastewater - HI84531
The HI84531 is an easy to use, fast and affordable automatic mini titrator designed for testing titratable alkalinity levels in water. Based on an acid base titration method, this mini titrator uses an optimized pre-programmed method of analysis with a powerful algorithm that determines the completion of the titration reaction by the use of a glass body pH electrode.
The HI84531 incorporates a precision piston style dosing pump that adjusts the volume of dosing dynamically based on the voltage change. This dosing system reduces the amount of time required for the titration while providing for a highly accurate determination of the amount of titrant used.
This mini titrator is supplied complete with all the materials necessary to perform low and high range measurements of alkalinity in water. All chemicals are premixed and prepackaged including standardized titrants, reagents and pump calibration solution. There is no need for volumetric glassware or analytical balances.
• Piston driven pump for accurate dynamic dosing
• Complete with glass double junction pH electrode
• Pre-standardized titrant and pre-measured reagents
Mini Titrator for Measuring Titratable Acidity in Dairy Products - HI84529
The HI84529 is an easy to use, fast and affordable automatic mini titrator designed for testing titratable acidity levels in dairy products. Based on an acid-base titration method, this mini titrator uses an optimized pre-programmed method of analysis with a powerful algorithm that determines the completion of the titration reaction by the use of a specialized foodcare pH electrode.
The HI84529 incorporates a precision piston style dosing pump that adjusts the volume of dosing dynamically based on the voltage change. This dosing system reduces the amount of time required for the titration while providing for a highly accurate determination of the amount of titrant used.
This mini titrator is supplied complete with all the materials necessary to perform low and high range measurements of titratable acidity. All chemicals are premixed and prepackaged including standardized titrants, reagents and pump calibration solution. There is no need for volumetric glassware or analytical balances.
• Piston driven pump for accurate dynamic dosing
• Complete with anti-clogging reference electrode
• Pre-standardized titrant and pre-measured reagents
Mini Titrator for Measuring Titratable Acidity in Water - HI84530
The HI84530 is an easy to use, fast and affordable, method specific titrator designed for testing titratable acidity levels in water. Based on an acid-base titration method, this mini titrator uses an optimized pre-programmed method of analysis with a powerful algorithm that determines the completion of the titration reaction potentiometrically with a glass body pH electrode.
The HI84530 incorporates a precision piston style dosing pump that adjusts the volume of dosing dynamically based on the voltage change. This type of dosing system reduces the amount of time required for the titration while providing for a highly accurate determination of the amount of titrant used.
This mini titrator is supplied complete with all the materials necessary to perform low and high range measurements of acidity in water. All chemicals are premixed and prepackaged including standardized titrants, reagents and pump calibration solution. There is no need for volumetric glassware or analytical balances.
• Piston driven pump for accurate dynamic dosing
• Pre-standardized titrant and pre-measured reagents
• Benchtop use as a pH/mV meter
Mini Titrator for Measuring Formol Number in Wine and Fruit Juice - HI84533
The HI84533 is a simple, fast, and affordable automatic mini titrator designed for testing formol number in wines or fruit juices. Based on an acid-base titration method, this mini titrator uses an optimized pre-programmed method of analysis with a powerful algorithm that determines the completion of the titration reaction by the use of a glass body pH electrode.
The HI84533 incorporates a precision piston style dosing pump that adjusts the volume of dosing dynamically based on the voltage change. This dosing system reduces the amount of time required for the titration while providing for a highly accurate determination of the amount of titrant used.
This mini titrator is supplied complete with all the materials necessary to perform low and high range formol measurements. All chemicals are premixed and prepackaged including standardized titrants, reagents and pump calibration solution. There is no need for volumetric glassware or analytical balances.