Optical LED Electrodes

Photometric Probe for Colorimetric Titrations at 470 nm - HI900604 HI900604

Photometric Probe for Colorimetric Titrations at 470 nm - HI900604

For many titrations, a potentiometric determination of the equivalence point is simply not possible. However, manually performing complexometric titrations can be inaccurate due to ambiguous color changes and when using non-aqueous or semi-opaque liquids, such as lubricating oils. In these cases, the use of a photometric probe for the optical determination of an endpoint during volumetric analysis is preferred. Hanna Instruments introduces HI900604 photometric electrode for when a color change is still the best solution.

• High color sensitivity in a compact design

• Chemically resistant glass-body construction

• Stable blue LED (470 nm) light source with low drift

Photometric Probe for Colorimetric Titrations at 625 nm - HI900602 HI900602

Photometric Probe for Colorimetric Titrations at 625 nm - HI900602

For many titrations, a potentiometric determination of the equivalence point is simply not possible. However, manually performing complexometric titrations can be inaccurate due to ambiguous color changes and when using non-aqueous or semi-opaque liquids, such as lubricating oils. In these cases, the use of a photometric probe for the optical determination of an endpoint during volumetric analysis is preferred. Hanna Instruments introduces HI900602 photometric electrode for when a color change is still the best solution.

• High color sensitivity in a compact design

• Chemically resistant glass-body construction

• Stable red LED (625 nm) light source with low drift

Photometric Probe for Colorimetric Titrations at 525 nm - HI900601 HI900601

Photometric Probe for Colorimetric Titrations at 525 nm - HI900601

 For many titrations, a potentiometric determination of the equivalence point is simply not possible. However, manually performing complexometric titrations can be inaccurate due to ambiguous color changes and when using non-aqueous or semi-opaque liquids, such as lubricating oils. In these cases, the use of a photometric probe for the optical determination of an endpoint during volumetric analysis is preferred. Hanna Instruments introduces HI900601 photometric electrode for when a color change is still the best solution.

• High color sensitivity in a compact design

• Chemically resistant glass-body construction

• Stable green LED (525 nm) light source with low drift

Photometric Probe for Colorimetric Titrations at 590 nm - HI900603 HI900603

Photometric Probe for Colorimetric Titrations at 590 nm - HI900603

For many titrations, a potentiometric determination of the equivalence point is simply not possible. However, manually performing complexometric titrations can be inaccurate due to ambiguous color changes and when using non-aqueous or semi-opaque liquids, such as lubricating oils. In these cases, the use of a photometric probe for the optical determination of an endpoint during volumetric analysis is preferred. Hanna Instruments introduces HI900603 photometric electrode for when a color change is still the best solution.

• High color sensitivity in a compact design

• Chemically resistant glass-body construction

• Stable yellow LED (590 nm) light source with low drift