Optical LED Electrodes
Photometric Probe for Colorimetric Titrations at 470 nm - HI900604
For many titrations, a potentiometric determination of the equivalence point is simply not possible. However, manually performing complexometric titrations can be inaccurate due to ambiguous color changes and when using non-aqueous or semi-opaque liquids, such as lubricating oils. In these cases, the use of a photometric probe for the optical determination of an endpoint during volumetric analysis is preferred. Hanna Instruments introduces HI900604 photometric electrode for when a color change is still the best solution.
• High color sensitivity in a compact design
• Chemically resistant glass-body construction
• Stable blue LED (470 nm) light source with low drift
Photometric Probe for Colorimetric Titrations at 625 nm - HI900602
For many titrations, a potentiometric determination of the equivalence point is simply not possible. However, manually performing complexometric titrations can be inaccurate due to ambiguous color changes and when using non-aqueous or semi-opaque liquids, such as lubricating oils. In these cases, the use of a photometric probe for the optical determination of an endpoint during volumetric analysis is preferred. Hanna Instruments introduces HI900602 photometric electrode for when a color change is still the best solution.
• High color sensitivity in a compact design
• Chemically resistant glass-body construction
• Stable red LED (625 nm) light source with low drift
Photometric Probe for Colorimetric Titrations at 525 nm - HI900601
For many titrations, a potentiometric determination of the equivalence point is simply not possible. However, manually performing complexometric titrations can be inaccurate due to ambiguous color changes and when using non-aqueous or semi-opaque liquids, such as lubricating oils. In these cases, the use of a photometric probe for the optical determination of an endpoint during volumetric analysis is preferred. Hanna Instruments introduces HI900601 photometric electrode for when a color change is still the best solution.
• High color sensitivity in a compact design
• Chemically resistant glass-body construction
• Stable green LED (525 nm) light source with low drift
Photometric Probe for Colorimetric Titrations at 590 nm - HI900603
For many titrations, a potentiometric determination of the equivalence point is simply not possible. However, manually performing complexometric titrations can be inaccurate due to ambiguous color changes and when using non-aqueous or semi-opaque liquids, such as lubricating oils. In these cases, the use of a photometric probe for the optical determination of an endpoint during volumetric analysis is preferred. Hanna Instruments introduces HI900603 photometric electrode for when a color change is still the best solution.