Reference
Glass Body General Purpose Reference Electrode
The HI5311 is a glass body, refillable, double junction, half-cell reference electrode with a 4 mm banana connector. This electrode has a single ceramic junction in the outer reference cell and is made for use in temperatures ranging from -5 to 100℃.
This design consideration is made for general purpose use with pH, ORP, or ion selective electrode half-cells, as well as for use in a variety of titrations.
• Half-Cell Design
• Refillable Electrode
• Double Junction Reference
Reference Electrode for Samples with Suspended Solids
The HI5312 is a glass body, refillable, double junction, half-cell reference electrode with a 4 mm banana connector. This electrode has a PTFE sleeve junction in the outer reference cell and is made for use in temperatures ranging from -5 to 80℃.
This design consideration is made for measurements in samples with suspended solids, and can also be used in a variety of titrations.
• Half-Cell Design
• Refillable Electrode
• PTFE Sleeve Junction
PEI Body Reference Electrode for FC301B
The HI5313 is a PEI body, refillable, single junction, half-cell reference electrode with a 4 mm banana connector. This electrode has a single ceramic junction in the outer reference cell and is made for use in temperatures ranging from -5 to 60℃.
This design consideration is made for use with the FC301B fluoride half-cell ion selective electrode.
• Half-Cell Design
• Durable PEI Body
• Gel Electrolyte
Glass Body Reference Electrode for Measurements with Remote Filling
The HI5314 is a glass body, refillable, double junction, half-cell reference electrode with a 4 mm banana connector. This electrode has a double ceramic junction in the outer reference cell and a side arm construction.
This design consideration is made for use in applications that require remote filling in temperatures ranging from -5 to 100℃.
• Refillable Electrode
• Double Ceramic Junction
• Side Arm Construction
Reference Electrode for ISE Half-Cells
The HI5315 reference electrode is a silver/silver chloride double junction half-cell designed for use with ion selective electrode (ISE) and pH half-cells.
The reference electrode provides a stable reference voltage when paired with a sensing half-cell. The external reference electrolyte chamber is refillable and easy to drain with the quick flush sleeve design. The internal reference elements are housed within a durable polyetherimide (PEI) body. A fast responding liquid junction, excellent reproducibility, and ease of use will mark this reference as the “best” in your lab.
• Skirted cone geometry
• Quick flush sleeve
• For use with ISE and pH half-cells
Glass Body Calomel Reference Electrode
The HI5412 is a glass body, refillable, double junction, half-cell reference electrode with a 4 mm banana connector. This electrode has a single ceramic junction in the outer reference cell and calomel references.
This design consideration is made for for use with ion selective electrodes, titrations, and general purpose applications in temperatures ranging from -5 to 60℃.
Half-Cell Electrode
Calomel References
Single Ceramic Junction
Glass Body Calomel Reference Electrode for Samples with Suspended Solids
The HI5413 is a glass body, refillable, single junction, half-cell reference electrode with a 4 mm banana connector. This electrode has a PTFE sleeve junction in the outer reference cell, calomel references, and is made for use in temperatures ranging from -5 to 60℃.
This design consideration is made for measurements in samples with suspended solids, and can be used in a variety of titrations.
• Half-Cell Design
• Calomel References
• PTFE Sleeve Junction
Glass Body Calomel Reference Electrode for Measurements with Remote Filling
The HI5414 is a glass body, refillable, double junction, half-cell reference electrode with a 4 mm banana connector. This electrode has a double ceramic junction in the outer reference cell, calomel references, and side arm construction.
This design consideration is made for use in applications that require remote filling in temperatures ranging from -5 to 60℃.