ISE Electrode
Copper Combination Ion-Selective Electrode (ISE)
The HI4108 is a solid state, combination ion-selective electrode (ISE) for the determination of cupric ions (Cu2+) in solution. The mixed cupric sulfide/silver sulfide sensing pellet produces a potential change due to the cupric ion exchange between the inorganic pellet membrane and the sample. The internal sensing elements are housed within a durable polyetherimide (PEI) body.
The HI4108 is ideal for a variety of applications in plating, wastewater, and industrial processes.
• Solid state sensor
• Skirted cone geometry
• Detection from 0.065 to 6, 355 mg/L Cu2+
Iodide Half-Cell Ion-Selective Electrode (ISE)
The HI4011 is a solid state, half-cell ion selective electrode (ISE) for the determination of iodide (I-) in solution. The silver iodide sensing pellet produces a potential change due to the iodide ion exchange between the inorganic pellet membrane and the sample. The internal sensing elements are housed within a durable epoxy body.
The HI4011 is ideal for a variety of applications in food production and environmental monitoring.
• Solid state sensor
• Detection from 0.01 to 127, 000 mg/L I-
• For use with HI5315 reference half-cell
Iodide ISE 0.1M Standard
HI4011-01 is a 500 mL bottle of premium quality 0.1M iodide standard solution.
Hanna ISE standards have the lot number and expiration date clearly marked on the label. Bottles are air tight with a tamper-proof seal to ensure the quality of the standard solution. Hanna’s line of standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
• 0.1M iodide standard
• Air tight bottle with tamper-proof seal
• Lot number and expiration date printed on each label
Iodide Combination Ion-Selective Electrode (ISE)
The HI4111 is a solid-state, combination ion-selective electrode (ISE) for the determination of iodide (I-) in solution. The silver iodide sensing pellet produces a potential change due to the iodide ion exchange between the inorganic pellet membrane and the sample. The internal sensing elements are housed within a durable polyetherimide (PEI) body.
The HI4111 is ideal for a variety of applications in food production and environmental monitoring.
• Solid state sensor
• Skirted cone geometry
• Detection from 0.01 to 127, 000 mg/L I-
Silver/Sulfide Half-Cell Ion-Selective Electrode (ISE)
The HI4015 is a solid state, half-cell ion selective electrode (ISE) for the determination of silver (Ag+) or sulfide (S2-) in solution. The silver/silver sulfide sensing pellet produces a potential change due to the ion exchange between the inorganic pellet membrane and the sample. The internal sensing elements are housed within a durable epoxy body.
The HI4015 is ideal for a variety of applications in water conditioning, environmental monitoring, and industrial processes.
• Solid state sensor
• Silver detection from 0.11 to 107, 900 mg/L Ag+
• Sulfide detection from 0.003 to 32, 100 mg/L S2-
• For use with HI5315 reference half-cell
Sulfide Antioxidant Buffer (SAOB) for Sulfide ISEs
HI4015-00 is a buffer solution for use with silver/sulfide ion selective electrodes. There are two components making up the HI4015-00: one 500 mL bottle of SAOB Reagent A and one 18 g bottle of SAOB Reagent B.
Hanna ISE solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
• Required for sulfide measurements
• Air tight bottle with tamper-proof seal
• Clearly marked lot number and expiration date
Silver ISE 0.1M Standard
HI4015-01 is a 500 mL bottle of premium quality 0.1M silver standard solution.
Hanna ISE standards have the lot number and expiration date clearly marked on the label. Bottles are air tight with a tamper-proof seal to ensure the quality of the standard solution. Hanna’s line of standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
• 0.1M silver standard
• Air tight bottle with tamper-proof seal
• Lot number and expiration date printed on each label
Silver/Sulfide Combination Ion-Selective Electrode (ISE)
The HI4115 is a solid state, combination ion selective electrode (ISE) for the determination of silver (Ag+) or sulfide (S2-) in solution. The silver/silver sulfide sensing pellet produces a potential change due to the ion exchange between the inorganic pellet membrane and the sample. The internal sensing elements are housed within a durable polyetherimide (PEI) body.
The HI4115 is ideal for a variety of applications in water conditioning, environmental monitoring, and industrial processes.
• Solid state sensor
• Skirted cone geometry
• Silver detection from 0.11 to 107, 900 mg/L Ag+
• Sulfide detection from 0.003 to 32, 100 mg/L S2-
Replacement pH Assembly for Ammonia ISE - HI4000-51
The HI4000-51 is a replacement pH reference assembly for the HI4101 ammonia gas sensing ion selective electrode.
- Combination pH assembly
- pH sensitive membrane
- Stable reference electrode
Replacement Membrane Cap for Ammonia ISE - HI4000-52
The HI4000-52 is a replacement membrane cap for the HI4101 ammonia gas sensing ion selective electrode.
• Secure screw cap
• Durable Delrin® material
Ammonia ISE 0.1M Standard - HI4001-01
HI4001-01 is a 500 mL bottle of premium quality 0.1M ammonia standard solution.
Hanna ISE standards have the lot number and expiration date clearly marked on the label. Bottles are air tight with a tamper-proof seal to ensure the quality of the standard solution. Hanna's line of standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
0.1M ammonia standard
Air tight bottle with tamper-proof seal
Lot number and expiration date printed on each label
Ammonia ISE 100 ppm Standard - HI4001-02
HI4001-02 is a 500 mL bottle of premium quality 100 ppm (mg/L) ammonia standard solution (as NH3-N).
Hanna ISE standards have the lot number and expiration date clearly marked on the label. Bottles are air tight with a tamper-proof seal to ensure the quality of the standard solution. Hanna's line of standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
100 ppm (mg/L) ammonia standard
Air tight bottle with tamper-proof seal
Lot number and expiration date printed on each label
Ammonia ISE 1000 ppm Standard - HI4001-03
HI4001-03 is a 500 mL bottle of premium quality 1000 ppm (mg/L) ammonia standard solution (as NH3-N).
Hanna ISE standards have the lot number and expiration date clearly marked on the label. Bottles are air tight with a tamper-proof seal to ensure the quality of the standard solution. Hanna’s line of standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
• 1000 ppm (mg/L) ammonia standard
• Air tight bottle with tamper-proof seal
• Lot number and expiration date printed on each label
Ammonia ISE Filling Solution - HI4001-40
HI4001-40 is a set of (4) 30 mL bottles of fill solution made specifically for Hanna’s ammonia gas sensing ion selective electrodes (ISEs).
The electrolyte solution should be added to the outer probe body of the HI4101 ISE before final assembly to ensure optimum performance.
• Fill solution for ammonia ion selective electrodes
• Convenient 30 mL bottles
• Clearly marked bottle with lot number and expiration date
Ammonia ISE Conditioning and Storage Solution - HI4001-45
HI4001-45 is a 500 mL bottle of conditioning and storage solution made specifically for Hanna’s ammonia gas sensing ion selective electrodes (ISEs).
The internal glass pH element of the ammonia ISE requires conditioning to ensure the sensing glass remains hydrated. The ammonia ISE can also remain assembled and stored in the HI4001-45 solution for short term storage purposes.