ISE Electrode

HI4001-51

Ammonia ISE Membrane Kit (20 pcs) - HI4001-51

The HI4001-51 is a replacement membrane kit for the ammonia gas sensing ion selective electrode.

• Selectively permeable membrane

• PTFE material

• Easy to replace

Ammonia Combination Ion-Selective Electrode (ISE) HI4101

Ammonia Combination Ion-Selective Electrode (ISE)

The HI4101 is a gas sensing, combination ion selective electrode (ISE) for the determination of ammonia (NH3) in solution. Its PTFE membrane allows for ammonia gas diffusion into a thin layer of internal electrolyte. The internal sensing elements are within a durable Delrin® body.

The HI4101 is ideal for a variety of applications including water, wastewater, agricultural, and wine applications.

• Replaceable PTFE membranes

• Durable Delrin® body

• Detection from 0.02 to 17, 000 mg/L NH3

HI4000-54

Replacement pH Assembly for Carbon Dioxide ISE - HI4000-54

The HI4000-54 is a replacement pH reference assembly for the HI4105 carbon dioxide gas sensing ion selective electrode.

• Combination pH assembly

• pH sensitive membrane

• Stable reference electrode

HI4005-00

Ionic Strength Adjuster (ISA) for Carbon Dioxide ISEs - HI4005-00

HI4005-00 is a 500 mL bottle of ionic strength adjuster (ISA) solution for use with carbon dioxide ion selective electrodes.

Hanna ISA solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna's line of solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.

Required for carbon dioxide ISE measurements

Air tight bottle with tamper-proof seal

Clearly marked lot number and expiration date

HI4005-01

Carbon Dioxide ISE 0.1M Standard - HI4005-01

HI4005-01 is a 500 mL bottle of premium quality 0.1M carbon dioxide standard solution.

Hanna ISE standards have the lot number and expiration date clearly marked on the label. Bottles are air tight with a tamper-proof seal to ensure the quality of the standard solution. Hanna’s line of standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.

• 0.1M carbon dioxide standard

• Air tight bottle with tamper-proof seal

• Lot number and expiration date printed on each label

Carbon Dioxide ISE 1000 ppm Standard HI4005-03

Carbon Dioxide ISE 1000 ppm Standard

HI4005-03 is a 500 mL bottle of premium quality 1000 mg/L (ppm) carbon dioxide standard solution (as CaCO3).

Hanna ISE standards have the lot number and expiration date clearly marked on the label. Bottles are air tight with a tamper-proof seal to ensure the quality of the standard solution. Hanna's line of standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.

1000 ppm (mg/L) carbon dioxide standard

Air tight bottle with tamper-proof seal

Lot number and expiration date printed on each label

Carbon Dioxide ISE Filling Solution HI4005-40

Carbon Dioxide ISE Filling Solution

HI4005-40 is a set of (4) 30 mL bottles of fill solution made specifically for Hanna’s carbon dioxide gas sensing ion selective electrodes (ISEs).

The electrolyte solution should be added to the outer probe body of the HI4105 ISE before final assembly to ensure optimum performance.

• Fill solution for carbon dioxide ion selective electrodes

• Convenient 30 mL bottles

• Clearly marked bottle with lot number and expiration date

Carbon Dioxide ISE Conditioning and Storage Solution HI4005-45

Carbon Dioxide ISE Conditioning and Storage Solution

HI4005-45 is a 500 mL bottle of conditioning and storage solution made specifically for Hanna's carbon dioxide gas sensing ion selective electrodes (ISEs).

The internal glass pH element of the carbon dioxide ISE requires conditioning to ensure the sensing glass remains hydrated. The carbon dioxide ISE can also remained assembled and stored in the HI4005-45 solution for short term storage purposes.

Effective conditioning and storage solution

Air tight bottle with tamper-proof seal

Clearly marked bottle with lot numner and expiration date

Carbon Dioxide ISE Membrane Kit (3 pcs) HI4005-53

Carbon Dioxide ISE Membrane Kit (3 pcs)

The HI4005-53 is a set of 3 replacement membranes for the HI4105 carbon dioxide gas sensing ion selective electrode.

• Selectively permeable membrane

• PTFE material

• Easy to replace

Carbon Dioxide Combination Ion-Selective Electrode (ISE) HI4105

Carbon Dioxide Combination Ion-Selective Electrode (ISE)

The HI4105 is a gas sensing, combination ion-selective electrode (ISE) for the determination of carbon dioxide (CO2) in solution. Its PTFE membrane allows for carbon dioxide gas diffusion into a thin layer of internal electrolyte. The internal sensing elements are within a durable Delrin® body.

The HI4105 is ideal for a variety of applications including water, beverage, and wine applications.

• Replaceable PTFE membranes

• Durable Delrin® body

• Detection from 17.6 to 880 mg/L CO2

Cyanide Half-Cell Ion-Selective Electrode (ISE) HI4009

Cyanide Half-Cell Ion-Selective Electrode (ISE)

The HI4009 is a solid state, half-cell ion selective electrode (ISE) for the determination of cyanide (CN-) in solution. The silver halide sensing pellet produces a potential change due to the cyanide ion exchange between the inorganic pellet membrane and the sample. The internal sensing elements are housed within a durable epoxy body.

The HI4009 is ideal for a variety of applications in plating, wastewater, and agriculture.

Solid state sensor

Detection from 0.026 to 260 mg/L CN-

For use with HI5315 reference half-cell

Cyanide Combination Ion-Selective Electrode (ISE) HI4109

Cyanide Combination Ion-Selective Electrode (ISE)

The HI4109 is a solid state, combination ion selective electrode (ISE) for the determination of cyanide (CN-) in solution. The silver halide sensing pellet produces a potential change due to the cyanide ion exchange between the inorganic pellet membrane and the sample. The internal sensing elements are housed within a durable polyetherimide (PEI) body.

The HI4109 is ideal for a variety of applications in plating, wastewater, and agriculture.

• Solid state sensor

• Skirted cone geometry

• Detection from 0.026 to 260 mg/L CN-

Lead/Sulfate Half-Cell Ion-Selective Electrode (ISE) HI4012

Lead/Sulfate Half-Cell Ion-Selective Electrode (ISE)

The HI4012 is a solid state, half-cell ion selective electrode (ISE) for the determination of lead (Pb2+) in solution and indicator for sulfate in titrations. The lead sulfide sensing pellet produces a potential change due to the ion exchange between the inorganic pellet membrane and the sample. The internal sensing elements are housed within a durable epoxy body.

The HI4012 is ideal for a variety of applications in the plating industry and environmental monitoring.

Solid state sensor

Detection from 0.21 to 20, 700 mg/L Pb2+

For use with HI5315 reference half-cell

Ionic Strength Adjuster (ISA) for Lead/Sulfate ISEs HI4012-00

Ionic Strength Adjuster (ISA) for Lead/Sulfate ISEs

HI4012-00 is 500 mL bottle of ionic strength adjuster (ISA) solution for use with lead/sulfate ion selective electrodes.

Hanna ISA solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.

• Required for lead measurements

• Air tight bottle with tamper-proof seal

• Clearly marked lot number and expiration date

Lead ISE 0.1M Standard HI4012-01

Lead ISE 0.1M Standard

HI4012-01 is a 500 mL bottle of premium quality 0.1M lead standard solution.

Hanna ISE standards have the lot number and expiration date clearly marked on the label. Bottles are air tight with a tamper-proof seal to ensure the quality of the standard solution. Hanna’s line of standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.

• 0.1M lead standard

• Air tight bottle with tamper-proof seal

• Lot number and expiration date printed on each label