Reagents

Titrant for Formol Number Mini Titrator - HI84533-50 HI84533-50

Titrant for Formol Number Mini Titrator - HI84533-50

The HI84533-50 is a 230 mL bottle of titrant solution for use with the HI84533 Formol Number Mini Titrator for Wine and Fruit Juice Analysis.

The HI84533-50 titrant solution is used for both the low and high ranges of formol number. The titrant is pre-standardized, eliminating the need for any volumetric glassware or a analytical balance and ensuring titrations are fast, accurate, and simple to perform.

• Pre-standardized titrant

• Clearly marked expiration date and lot number

• Air tight bottle with tamper-proof seal

Pump Calibration Standard for Formol Number Mini Titrator - HI84533-55 HI84533-55

Pump Calibration Standard for Formol Number Mini Titrator - HI84533-55

The HI84533-55 is a 120 mL bottle of pump calibration solution that is used to calibrate the dosing system of the HI84533 Formol Number Mini Titrator for Wine and Fruit Juice Analysis.

A calibrated dosing pump allows for the accurate determination of the amount of titrant used when performing a titration. The amount of volume dosed along with the concentration of the titrant is used by the pre-programmed formula within the HI84533 in determining the exact amount of total assimilable nitrogen. The pump calibration procedure should be performed anytime the titrant or pH electrode is replaced. Routine calibration is recommended to ensure the highest of accuracy when performing a titration.

• Pre-measured solution

• Clearly marked expiration date and lot number

• Air tight bottle with tamper-proof seal

Hydrogen Peroxide Reagent for Formol Number Mini Titrator - HI84533-60 HI84533-60

Hydrogen Peroxide Reagent for Formol Number Mini Titrator - HI84533-60

The HI84533-60 is a 30 mL bottle of hydrogen peroxide reagent that is used for samples on the HI84533 Formol Number Mini Titrator for Wine and Fruit Juice Analysis.

The HI84533 mini titrator is designed to determine both low and high range values of formol number in wine and fruit juice. Wine or fruit juice samples containing high levels of sulfur dioxide (SO2) may introduce error in determining formol number. With such samples, it is necessary to add several drops of HI84533-60 hydrogen peroxide reagent to neutralize the SO2 prior to titration.

Pre-measured solution

Clearly marked expiration date and lot number

Air tight bottle with tamper-proof seal

Formol Base Reagent for Formol Number Mini Titrator - HI84533-61 HI84533-61

Formol Base Reagent for Formol Number Mini Titrator - HI84533-61

The HI84533-61 is a 230 mL bottle of formol base reagent required for wine and fruit juice samples using the HI84533 Formol Number Mini Titrator for Wine and Fruit Juice Analysis.

The formol base reagent is used to ensure adequate reaction with amino acids and nitrogen compounds present in wine or fruit juice samples. This reaction frees hydrogen ions in an amount proportional to the available nitrogen, which the titrant neutralizes to provide an accurate determination of total assimilable nitrogen.

• Pre-measured solution

• Clearly marked expiration date and lot number

• Air tight bottle with tamper-proof seal

pH Adjustment Reagent for Formol Number Mini Titrator - HI84533-62 HI84533-62

pH Adjustment Reagent for Formol Number Mini Titrator - HI84533-62

The HI84533-62 is a 30 mL bottle of pH adjustment reagent that is used for samples on the HI84533 Formol Number Mini Titrator for Wine and Fruit Juice Analysis.

The HI84533 mini titrator is designed to determine both low and high range values of formol number in wine and fruit juice. Determination requires the addition of HI84533-62 pH adjustment reagent to raise the pH value of the sample before addition of formol reagent and subsequent titration.

• Pre-measured solution

• Clearly marked expiration date and lot number

• Air tight bottle with tamper-proof seal

Pump Calibration Standard for Titratable Alkalinity in Water Mini Titrator - HI84531-55 HI84531-55

Pump Calibration Standard for Titratable Alkalinity in Water Mini Titrator - HI84531-55

The HI84531-55 is a 230 mL bottle of pump calibration solution that is used to calibrate the dosing system of the HI84531 Titratable Alkalinity Mini Titrator for Water Analysis.

A calibrated dosing pump allows for the accurate determination of the amount of titrant used when performing a titration. The amount of volume dosed along with the concentration of the titrant is used by the pre-programmed formula within the HI84531 in determining the exact titratable alkalinity. The pump calibration procedure should be performed anytime the titrant or pH electrode is replaced. Routine calibration is recommended to ensure the highest of accuracy when performing a titration.

• Pre-measured solution

• Clearly marked expiration date and lot number

• Air tight bottle with tamper-proof seal

Dispersing Agent - HI93703-51 HI93703-51

Dispersing Agent - HI93703-51

HI93703-51 Dispersing agent is for use with specific methods in Hanna’s line of photometers. This easy to use dropper bottle ensures that any unwanted turbidity present in the sample is removed prior to measurement, helping to provide accurate readings every time.

• Convenient dropper bottle

• Marked with expiration date and lot number

• Light tight bottle

Glycine Powder Reagents (100 tests) - HI93703-52 HI93703-52

Glycine Powder Reagents (100 tests) - HI93703-52

The HI93703-52 are glycine powder reagents used to remove chlorine interference when performing a colorimetric determination for ozone. There are enough reagents for 100 tests to be used with a compatible benchtop photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.

• Pre-made reagents for ease of use

• Prepared with high purity chemicals

• Marked with expiration date and lot number for traceability

Chlorine Remover Reagent - HI93703-53 HI93703-53

Chlorine Remover Reagent - HI93703-53

The HI93703-53 is a chlorine remover reagent used to remove chlorine interference when performing a colorimetric determination. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each bottle for traceability.

• Pre-made reagent for ease of use

• Prepared with high purity chemicals

• Marked with expiration date and lot number for traceability

Activated Carbon (50 packets) - HI93703-55 HI93703-55

Activated Carbon (50 packets) - HI93703-55

HI93703-55 Activated Carbon packets are for use with Hanna’s HI83225 Nutrient Analysis benchtop photometer. These packets are for sample preparation of irrigation water to remove color or turbidity. These easy to use packets ensures the proper amount of activated carbon is added to prepare the sample.

• Convenient pre-measured packets

• Marked with expiration date and lot number

• Remove color and turbidity from samples

Glycerol Standard (30 mL x 4) for Honey and Maple Syrup Photometers - HI93703-57 HI93703-57

Glycerol Standard (30 mL x 4) for Honey and Maple Syrup Photometers - HI93703-57

The HI93703-57 is a reagent grade glycerol reference standard used in the calibration of the HI96785 Honey Color Analyzer and HI96759 Maple Syrup Photometer. The glycerol is used to calibrate the photometers to 100% transmittance. A honey or maple syrup sample is then tested to determine the amount of light, at a specific wavelength, can be transmitted relative to the glycerol standard. The % transmittance is then used to grade the appropriate product. For honey the results are reported as pfund mm while for maple syrup % transmittance is used. The HI93703-57 is for 4 bottles containing 30 mL of glycerol.

• Convenient bottles

• Sealed for freshness

• Expiration date on label

Activated Charcoal (10 g) - HI93703-59 HI93703-59

Activated Charcoal (10 g) - HI93703-59

The HI93703-59 activated charcoal reagent is for the colorimetric determination of reducing sugar concentration in wine using the HI83746 photometer. This high quality reagent is manufactured in our state-of-the-art facility and is clearly marked with the lot number and expiration date on each bottle for traceability.

• Pre-made reagents for ease of use

• Prepared with high-purity chemicals

• Marked with expiration date and lot number for traceability