Products

HI4003-01

Cadmium ISE 0.1M Standard - HI4003-01

HI4003-01 is a 500 mL bottle of premium quality 0.1M cadmium standard solution.

Hanna ISE standards have the lot number and expiration date clearly marked on the label. Bottles are air tight with a tamper-proof seal to ensure the quality of the standard solution. Hanna’s line of standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.

• 0.1M cadmium standard

• Air tight bottle with tamper-proof seal

• Lot number and expiration date printed on each label

Cadmium Combination Ion-Selective Electrode (ISE) HI4103

Cadmium Combination Ion-Selective Electrode (ISE)

The HI4103 is a solid state, combination ion selective electrode (ISE) for the determination of cadmium (Cd2+) in solution. The mixed cadmium sulfide/silver sulfide sensing pellet produces a potential change due to the cadmium ion exchange between the inorganic pellet membrane and the sample. The internal sensing elements are housed within a durable polyetherimide (PEI) body.

The HI4103 is ideal for a variety of applications in electroplating, battery construction, and in the laboratory.

• Solid state sensor

• Skirted cone geometry

• Detection from 0.01 to 11, 200 mg/L Cd2+

Chloride Half-Cell Ion-Selective Electrode (ISE) HI4007

Chloride Half-Cell Ion-Selective Electrode (ISE)

The HI4007 is a solid state, half-cell ion selective electrode (ISE) for the determination of chloride (Cl-) in solution. The silver chloride sensing pellet produces a potential change due to the chloride ion exchange between the inorganic pellet membrane and the sample. The internal sensing elements are housed within an epoxy body.

The HI4007 is ideal for a variety of applications in food and beverages, agriculture, and water treatment.

• Solid state sensor

• Detection from 1.8 to 35, 500 mg/L Cl-

• For use with HI5315 reference half-cell

Chloride ISE 0.1M Standard HI4007-01

Chloride ISE 0.1M Standard

HI4007-01 is a 500 mL bottle of premium quality 0.1M chloride standard solution.

Hanna ISE standards have the lot number and expiration date clearly marked on the label. Bottles are air tight with a tamper-proof seal to ensure the quality of the standard solution. Hanna’s line of standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.

• 0.1M chloride standard

• Air tight bottle with tamper-proof seal

• Lot number and expiration date printed on each label

Chloride ISE 100 ppm Standard HI4007-02

Chloride ISE 100 ppm Standard

HI4007-02 is a 500 mL bottle of premium quality 100 mg/L (ppm) chloride standard solution.

Hanna ISE standards have the lot number and expiration date clearly marked on the label. Bottles are air tight with a tamper-proof seal to ensure the quality of the standard solution. Hanna’s line of standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.

• 100 ppm (mg/L) chloride standard

• Air tight bottle with tamper-proof seal

• Lot number and expiration date printed on each label

Chloride ISE 1000 ppm Standard HI4007-03

Chloride ISE 1000 ppm Standard

HI4007-03 is a 500 mL bottle of premium quality 1000 mg/L (ppm) chloride standard solution.

Hanna ISE standards have the lot number and expiration date clearly marked on the label. Bottles are air tight with a tamper-proof seal to ensure the quality of the standard solution. Hanna’s line of standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.

• 1000 ppm (mg/L) chloride standard

• Air tight bottle with tamper-proof seal

• Lot number and expiration date printed on each label

Chloride Combination Ion-Selective Electrode (ISE) HI4107

Chloride Combination Ion-Selective Electrode (ISE)

The HI4107 is a solid state, combination ion selective electrode (ISE) for the determination of chloride (Cl-) in solution. The silver chloride sensing pellet produces a potential change due to the chloride ion exchange between the inorganic pellet membrane and the sample. The internal sensing elements are housed within a durable polyetherimide (PEI) body.

The HI4107 is ideal for a variety of applications in food and beverages, agriculture, and water treatment.

• Solid state sensor

• Skirted cone geometry

• Detection from 1.8 to 35, 500 mg/L Cl-

Copper Half-Cell Ion Selective Electrode (ISE) HI4008

Copper Half-Cell Ion Selective Electrode (ISE)

The HI4008 is a solid state, half-cell ion selective electrode (ISE) for the determination of cupric ions (Cu2+) in solution. The mixed cupric sulfide/silver sulfide sensing pellet produces a potential change due to the cupric ion exchange between the inorganic pellet membrane and the sample. The internal sensing elements are housed within a durable epoxy body.

The HI4008 is ideal for a variety of applications in plating, wastewater, and industrial processes.

• Solid state sensor

• Detection from 0.065 to 6, 355 mg/L Cu2+

• For use with HI5315 reference half-cell

Cupric ISE 0.1M Standard HI4008-01

Cupric ISE 0.1M Standard

HI4008-01 is a 500 mL bottle of premium quality 0.1M cupric standard solution.

Hanna ISE standards have the lot number and expiration date clearly marked on the label. Bottles are air tight with a tamper-proof seal to ensure the quality of the standard solution. Hanna’s line of standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.

• 0.1M cupric standard

• Air tight bottle with tamper-proof seal

• Lot number and expiration date printed on each label

Copper Combination Ion-Selective Electrode (ISE) HI4108

Copper Combination Ion-Selective Electrode (ISE)

The HI4108 is a solid state, combination ion-selective electrode (ISE) for the determination of cupric ions (Cu2+) in solution. The mixed cupric sulfide/silver sulfide sensing pellet produces a potential change due to the cupric ion exchange between the inorganic pellet membrane and the sample. The internal sensing elements are housed within a durable polyetherimide (PEI) body.

The HI4108 is ideal for a variety of applications in plating, wastewater, and industrial processes.

• Solid state sensor

• Skirted cone geometry

• Detection from 0.065 to 6, 355 mg/L Cu2+

Iodide Half-Cell Ion-Selective Electrode (ISE) HI4011

Iodide Half-Cell Ion-Selective Electrode (ISE)

The HI4011 is a solid state, half-cell ion selective electrode (ISE) for the determination of iodide (I-) in solution. The silver iodide sensing pellet produces a potential change due to the iodide ion exchange between the inorganic pellet membrane and the sample. The internal sensing elements are housed within a durable epoxy body.

The HI4011 is ideal for a variety of applications in food production and environmental monitoring.

• Solid state sensor

• Detection from 0.01 to 127, 000 mg/L I-

• For use with HI5315 reference half-cell

Iodide ISE 0.1M Standard HI4011-01

Iodide ISE 0.1M Standard

HI4011-01 is a 500 mL bottle of premium quality 0.1M iodide standard solution.

Hanna ISE standards have the lot number and expiration date clearly marked on the label. Bottles are air tight with a tamper-proof seal to ensure the quality of the standard solution. Hanna’s line of standards have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.

• 0.1M iodide standard

• Air tight bottle with tamper-proof seal

• Lot number and expiration date printed on each label

Iodide Combination Ion-Selective Electrode (ISE) HI4111

Iodide Combination Ion-Selective Electrode (ISE)

The HI4111 is a solid-state, combination ion-selective electrode (ISE) for the determination of iodide (I-) in solution. The silver iodide sensing pellet produces a potential change due to the iodide ion exchange between the inorganic pellet membrane and the sample. The internal sensing elements are housed within a durable polyetherimide (PEI) body.

The HI4111 is ideal for a variety of applications in food production and environmental monitoring.

• Solid state sensor

• Skirted cone geometry

• Detection from 0.01 to 127, 000 mg/L I-

Silver/Sulfide Half-Cell Ion-Selective Electrode (ISE) HI4015

Silver/Sulfide Half-Cell Ion-Selective Electrode (ISE)

The HI4015 is a solid state, half-cell ion selective electrode (ISE) for the determination of silver (Ag+) or sulfide (S2-) in solution. The silver/silver sulfide sensing pellet produces a potential change due to the ion exchange between the inorganic pellet membrane and the sample. The internal sensing elements are housed within a durable epoxy body.

The HI4015 is ideal for a variety of applications in water conditioning, environmental monitoring, and industrial processes.

• Solid state sensor

• Silver detection from 0.11 to 107, 900 mg/L Ag+

• Sulfide detection from 0.003 to 32, 100 mg/L S2-

• For use with HI5315 reference half-cell

Sulfide Antioxidant Buffer (SAOB) for Sulfide ISEs HI4015-00

Sulfide Antioxidant Buffer (SAOB) for Sulfide ISEs

HI4015-00 is a buffer solution for use with silver/sulfide ion selective electrodes. There are two components making up the HI4015-00: one 500 mL bottle of SAOB Reagent A and one 18 g bottle of SAOB Reagent B.

Hanna ISE solutions have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.

• Required for sulfide measurements

• Air tight bottle with tamper-proof seal

• Clearly marked lot number and expiration date