Ion Selective Electrodes (ISE)

Glass Body Calomel Reference Electrode HI5412

Glass Body Calomel Reference Electrode

The HI5412 is a glass body, refillable, double junction, half-cell reference electrode with a 4 mm banana connector. This electrode has a single ceramic junction in the outer reference cell and calomel references.

This design consideration is made for for use with ion selective electrodes, titrations, and general purpose applications in temperatures ranging from -5 to 60℃.

Half-Cell Electrode

Calomel References

Single Ceramic Junction

Glass Body Calomel Reference Electrode for Samples with Suspended Solids HI5413

Glass Body Calomel Reference Electrode for Samples with Suspended Solids

The HI5413 is a glass body, refillable, single junction, half-cell reference electrode with a 4 mm banana connector. This electrode has a PTFE sleeve junction in the outer reference cell, calomel references, and is made for use in temperatures ranging from -5 to 60℃.

This design consideration is made for measurements in samples with suspended solids, and can be used in a variety of titrations.

• Half-Cell Design

• Calomel References

• PTFE Sleeve Junction

Glass Body Calomel Reference Electrode for Measurements with Remote Filling HI5414

Glass Body Calomel Reference Electrode for Measurements with Remote Filling

The HI5414 is a glass body, refillable, double junction, half-cell reference electrode with a 4 mm banana connector. This electrode has a double ceramic junction in the outer reference cell, calomel references, and side arm construction.

This design consideration is made for use in applications that require remote filling in temperatures ranging from -5 to 60℃.

• Refillable Electrode

• Calomel References

• Side Arm Construction

10 ppm Ammonium Calibration Standard Sachets for HI9829 (25 x 20 mL) - HI9829-10 HI9829-10

10 ppm Ammonium Calibration Standard Sachets for HI9829 (25 x 20 mL) - HI9829-10

HI9829-10 is a premium quality 10 ppm (mg/L) Ammonium Nitrogen (NH4+-N) calibration standard. The standard is used to calibrate the HI7609829-10 ammonium ISE. Each sachet has the lot number and expiration date stamped on it. The sachet is made of light block and air-tight foil ensuring freshness each time one is used. The HI9829-10 contains 25 sachets, each with approximately 20 mL of Ammonium Calibration Standard (as N).

• Pre-mixed to exact standard value

• pH and ionic strength stabilized

• Lot number and expiration date on each sachet

10 ppm and 100 ppm Ammonium Calibration Standard Sachets for HI9829 (10 x 20 mL each) - HI9829-10/11 HI9829-10/11

10 ppm and 100 ppm Ammonium Calibration Standard Sachets for HI9829 (10 x 20 mL each) - HI9829-10/11

HI9829-10/11 is for premium quality 10 ppm and 100 ppm (mg/L) Ammonium (as N) calibration standards. These standards are used to calibrate the HI7609829-10 ammonium ISE. Each sachet has the lot number and expiration date stamped on it. The sachet is made of light block and air-tight foil ensuring freshness each time one is used. The HI9829-10/11 contains 10 sachets, each of the 10 ppm and 100 ppm Ammonium Calibration Standard (as N). Each sachet contains approximately 20 mL of buffer.

• Pre-mixed to exact standard value

• pH and ionic strength stabilized

• Lot number and expiration date on each sachet

100 ppm Ammonium Calibration Standard Sachets for HI9829 (25 x 20 mL) - HI9829-11 HI9829-11

100 ppm Ammonium Calibration Standard Sachets for HI9829 (25 x 20 mL) - HI9829-11

HI9829-11 is a premium quality 100 ppm (mg/L) Ammonium Nitrogen (NH4+-N) calibration standard. The standard is used to calibrate the HI7609829-10 ammonium ISE. Each sachet has the lot number and expiration date stamped on it. The sachet is made of light block and air-tight foil ensuring freshness each time one is used. The HI9829-10 is for 25 sachets containing approximately 20 mL of Ammonium Calibration Standard (as N).

• Pre-mixed to exact standard value

• pH and ionic strength stabilized

• Lot number and expiration date on each sachet

10 ppm Chloride Calibration Standard Sachets for HI9829 (25 x 25 mL) - HI9829-12 HI9829-12

10 ppm Chloride Calibration Standard Sachets for HI9829 (25 x 25 mL) - HI9829-12

HI9829-12 is a premium quality 10 ppm (mg/L) chloride calibration standard. The standard is used to calibrate the HI7609829-11 Chloride ISE. Each sachet has the lot number and expiration date stamped on it. The sachet is made of light block and air-tight foil ensuring freshness each time one is used.  The HI9829-12 is for 25 sachets containing approximately 25 mL of buffer.

• Pre-mixed to exact standard value

• pH and ionic strength stabilized

• Lot number and expiration date on each sachet

10 ppm and 100 ppm Chloride Calibration Standard Sachets for HI9829 (10 x 25 mL each) - HI9829-12/13 HI9829-12/13

10 ppm and 100 ppm Chloride Calibration Standard Sachets for HI9829 (10 x 25 mL each) - HI9829-12/13

HI9829-12/13 is for premium quality 10 ppm and 100 ppm (mg/L) Chloride calibration standards. These standards are used to calibrate the HI7609829-11 Chloride ISE. Each sachet has the lot number and expiration date stamped on it. The sachet is made of light block and air-tight foil ensuring freshness each time one is used. The HI9829-12/13 is for 10 sachets each of the 10 ppm and 100 ppm chloride calibration standard. Each sachet contains approximately 20 mL of buffer.

• Pre-mixed to exact standard value

• pH and ionic strength stabilized

• Lot number and expiration date on each sachet

100 ppm Chloride Calibration Standard Sachets for HI9829 (25 x 25 mL) - HI9829-13 HI9829-13

100 ppm Chloride Calibration Standard Sachets for HI9829 (25 x 25 mL) - HI9829-13

HI9829-13 is a premium quality 100 ppm (mg/L) chloride calibration standard. The standard is used to calibrate the HI7609829-11 Chloride ISE. Each sachet has the lot number and expiration date stamped on it. The sachet is made of light block and air-tight foil ensuring freshness each time one is used. Hanna’s line of calibration standards have been formulated to have an expiration of 5 years from the date of manufacture for an unopened sachet. The HI9829-13 is for 25 sachets containing approximately 25 mL of buffer.

• Pre-mixed to exact standard value

• pH and ionic strength stabilized

• Lot number and expiration date on each sachet

10 ppm and 100 ppm Nitrate (as N) Calibration Standard Sachets for HI9829 (10 x 25 mL each) - HI9829-14/15 HI9829-14/15

10 ppm and 100 ppm Nitrate (as N) Calibration Standard Sachets for HI9829 (10 x 25 mL each) - HI9829-14/15

HI9829-14/15 is for premium quality 10 ppm and 100 ppm (mg/L) Nitrate (as N) standard for calibration. These standards are used to calibrate the HI7609829-12 Nitrate ISE. Each sachet has the lot number and expiration date stamped on it. The sachet is made of light block and air-tight foil ensuring freshness each time one is used. The HI9829-14/15 is for 10 sachets each of the 10 ppm and 100 ppm chloride calibration standard. Each sachet contains approximately 20 mL of buffer.

• Pre-mixed to exact standard value

• pH and ionic strength stabilized

• Lot number and expiration date on each sachet

10 ppm Nitrate Standard (as N) Sachets for HI9829 (25 x 25 mL) - HI9829-14 HI9829-14

10 ppm Nitrate Standard (as N) Sachets for HI9829 (25 x 25 mL) - HI9829-14

HI9829-14 is a premium quality 10 ppm Nitrate Standard (as N) calibration standard. The standard is used to calibrate the HI7609829-12 Nitrate ISE. Each sachet has the lot number and expiration date stamped on it. The sachet is made of light block and air-tight foil ensuring freshness each time one is used. The HI9829-14 is for 25 sachets containing approximately 25 mL of buffer.

• Pre-mixed to exact standard value

• pH and ionic strength stabilized

• Lot number and expiration date on each sachet

100 ppm Nitrate Standard (as N) Sachets for HI9829 (25 x 25 mL) - HI9829-15 HI9829-15

100 ppm Nitrate Standard (as N) Sachets for HI9829 (25 x 25 mL) - HI9829-15

HI9829-15 is a premium quality 100 ppm Nitrate Standard (as N) calibration standard. The standard is used to calibrate the HI7609829-12 Nitrate ISE. Each sachet has the lot number and expiration date stamped on it. The sachet is made of light block and air-tight foil ensuring freshness each time one is used. Hanna’s line of calibration standards have been formulated to have an expiration of 5 years from the date of manufacture for an unopened sachet. The HI9829-14 is for 25 sachets containing approximately 25 mL of buffer.

• Pre-mixed to exact standard value

• pH and ionic strength stabilized

• Lot number and expiration date on each sachet

HI7072 Electrolyte Fill Solution, 1M KNO₃ (30 mL x 4) HI7072

HI7072 Electrolyte Fill Solution, 1M KNO₃ (30 mL x 4)

HI7072 is a 1M KNO3 electrode fill solution for use in double junction and ion selective electrodes. The electrolyte level in refillable electrodes should be checked before performing any measurements. If the level is low, refill with the proper electrolyte solution to ensure optimum performance. This simple maintenance helps guarantee adequate head pressure to promote the flow of reference electrolyte into the sample being measured.

• Fill solution for double junction and ion selective electrodes

• Convenient 30 mL bottles

• Clearly marked bottle with expiration date and lot number