Process Analyzer & Controller

Conductivity Transmitters to use with Four-ring Probe - HI8936-0 to 1999 µS/cm-With LCD HI8936CLN

Conductivity Transmitters to use with Four-ring Probe - HI8936-0 to 1999 µS/cm-With LCD

HI8936 is a conductivity transmitter that utilizes a four-ring potentiometric probe. This probe is virtually immune to contamination by unclean solutions. This allows the transmitter to operate at peak performance at all times.

• Automatic temperature compensation ensures fast, accurately compensated readings even during sudden temperature fluctuations.

• Optional backlit, LCD display for easy viewing.

Conductivity Transmitters to use with Four-ring Probe - HI8936-0 to 1999 µS/cm-Without LCD HI8936CN

Conductivity Transmitters to use with Four-ring Probe - HI8936-0 to 1999 µS/cm-Without LCD

HI8936 is a conductivity transmitter that utilizes a four-ring potentiometric probe. This probe is virtually immune to contamination by unclean solutions. This allows the transmitter to operate at peak performance at all times.

• Automatic temperature compensation ensures fast, accurately compensated readings even during sudden temperature fluctuations.

• Optional backlit, LCD display for easy viewing.

Conductivity Transmitters to use with Four-ring Probe - HI8936-0.0 to 199.9 µS/cm-With LCD HI8936DLN

Conductivity Transmitters to use with Four-ring Probe - HI8936-0.0 to 199.9 µS/cm-With LCD

HI8936 is a conductivity transmitter that utilizes a four-ring potentiometric probe. This probe is virtually immune to contamination by unclean solutions. This allows the transmitter to operate at peak performance at all times.

• Automatic temperature compensation ensures fast, accurately compensated readings even during sudden temperature fluctuations.

• Optional backlit, LCD display for easy viewing.

Conductivity Transmitters to use with Four-ring Probe - HI8936-0.0 to 199.9 µS/cm-Without LCD HI8936DN

Conductivity Transmitters to use with Four-ring Probe - HI8936-0.0 to 199.9 µS/cm-Without LCD

HI8936 is a conductivity transmitter that utilizes a four-ring potentiometric probe. This probe is virtually immune to contamination by unclean solutions. This allows the transmitter to operate at peak performance at all times.

• Automatic temperature compensation ensures fast, accurately compensated readings even during sudden temperature fluctuations.

• Optional backlit, LCD display for easy viewing.

pH Analog Controller with Dual Output and Self-Diagnostic Test – HI8711 HI8711

pH Analog Controller with Dual Output and Self-Diagnostic Test – HI8711

HI8711 allows the selection of two set points with two independent outputs for acid and alkaline dosages.

• Auto-diagnostics to verify offset, slope calibration, and electrode contamination/deterioration

• Hanna’s exclusive Fail Safe Alarm System protects against risks typical of industrial environments

• Selectable manual ON, OFF and automatic dosing control for alkaline and acid dosing with indicator

• 0.2 to 3.00 pH alarm tolerance range

ORP Analog Controller with Self-Diagnostic Test – HI8720 HI8720

ORP Analog Controller with Self-Diagnostic Test – HI8720

HI8720 ORP panel mounted controller is ideal for process control monitoring in a wide range of industrial applications, allowing for the selection of a set point for oxidizing or reducing dosage.

• Auto-diagnostic tests for electrode and instrument status.

• Displays values on the easy to read LCD.

• A removable, transparent splash-proof cover protects the front panel.

pH and EC Transmitter with Isolated Output - 0 - 1 V HI98143-01

pH and EC Transmitter with Isolated Output - 0 - 1 V

The HI98143 is part of a family of blind transmitter that can be used in water treatment and hydroponic applications. These meters have inputs for both pH and EC probes. The pH probe input uses a common BNC connector while EC has a direct wire connection for use with Hanna's EC probes that incorporate an NTC sensor for temperature compensation.

The HI98143 is available in four models based on the analog output signal required.

• Blind transmitter for pH and EC (up to 10 mS/cm)

• Choice of analog output in voltage or current

• Powered or loop powered analog outputs

pH and EC Transmitter with Isolated Output - 0 - 4 V HI98143-04

pH and EC Transmitter with Isolated Output - 0 - 4 V

The HI98143 is part of a family of blind transmitter that can be used in water treatment and hydroponic applications. These meters have inputs for both pH and EC probes. The pH probe input uses a common BNC connector while EC has a direct wire connection for use with Hanna's EC probes that incorporate an NTC sensor for temperature compensation.

The HI98143 is available in four models based on the analog output signal required.

• Blind transmitter for pH and EC (up to 10 mS/cm)

• Choice of analog output in voltage or current

• Powered or loop powered analog outputs

pH and EC Transmitter with Isolated Output - 4 - 20 mA (passive) HI98143-20

pH and EC Transmitter with Isolated Output - 4 - 20 mA (passive)

The HI98143 is part of a family of blind transmitter that can be used in water treatment and hydroponic applications. These meters have inputs for both pH and EC probes. The pH probe input uses a common BNC connector while EC has a direct wire connection for use with Hanna's EC probes that incorporate an NTC sensor for temperature compensation.

The HI98143 is available in four models based on the analog output signal required.

• Blind transmitter for pH and EC (up to 10 mS/cm)

• Choice of analog output in voltage or current

• Powered or loop powered analog outputs

pH and EC Transmitter with Isolated Output - 4 - 20 mA (active) HI98143-22

pH and EC Transmitter with Isolated Output - 4 - 20 mA (active)

The HI98143 is part of a family of blind transmitter that can be used in water treatment and hydroponic applications. These meters have inputs for both pH and EC probes. The pH probe input uses a common BNC connector while EC has a direct wire connection for use with Hanna's EC probes that incorporate an NTC sensor for temperature compensation.

The HI98143 is available in four models based on the analog output signal required.

• Blind transmitter for pH and EC (up to 10 mS/cm)

• Choice of analog output in voltage or current

• Powered or loop powered analog outputs

Chlorine, pH, ORP, and Temperature Analyzers - PCA300 Series-PCA330 Chlorine, pH, ORP & Temperature PCA330-1

Chlorine, pH, ORP, and Temperature Analyzers - PCA300 Series-PCA330 Chlorine, pH, ORP & Temperature

The Hanna Instruments PCA310, PCA320, PCA330 and PCA340 series of chlorine, pH, ORP and temperature analyzers are microprocessor controlled, process analyzers which continuously monitor a sample stream for chlorine content, pH, ORP and temperature values.

• 4 models available for monitoring chlorine, pH, and ORP levels.

• Two separate selectable 0-20 or 4-20 mA signal output (PCA340 only)

• User-friendly interface simplifies setup and maintenance.

Chlorine, pH, ORP, and Temperature Analyzers - PCA300 Series-PCA330 Chlorine, pH, ORP & Temperature PCA330-2

Chlorine, pH, ORP, and Temperature Analyzers - PCA300 Series-PCA330 Chlorine, pH, ORP & Temperature

The Hanna Instruments PCA310, PCA320, PCA330 and PCA340 series of chlorine, pH, ORP and temperature analyzers are microprocessor controlled, process analyzers which continuously monitor a sample stream for chlorine content, pH, ORP and temperature values.

• 4 models available for monitoring chlorine, pH, and ORP levels.

• Two separate selectable 0-20 or 4-20 mA signal output (PCA340 only)

• User-friendly interface simplifies setup and maintenance.