Electrodes & Probes
pH Electrode with Clogging Prevention System (CPS™) and BNC + Pin Connector - HI1048P
The HI1048P is a glass body, refillable, sleeve junction pH electrode with a BNC and pin connector. The pin connector is used to enable the CAL Check function of the HI2221, HI2222, and HI2223 benchtop meters.
This electrode features a double junction reference, Hanna’s Clogging Prevention System (CPS™) technology and spherical glass sensing bulb made with general purpose glass. This pH electrode is ideal for wine must and juice due to their high solids content that would clog a standard general purpose pH electrode.
• Clogging Prevention System (CPS™) Technology
• Refillable Electrode
• Double Junction Design
pH Electrode with Conical Tip and Quick Connect DIN Connector - HI10533
The HI10533 is a glass body, refillable, double junction pH electrode that has a built-in temperature sensor and connects to the meter with a Quick Connect DIN connector. This type of connector is proprietary to specific meters.
• Built-In Temperature Sensor
• Triple Ceramic Junction
• Refillable Electrode
>pH Electrode with Conical Tip and BNC + Pin Connector - HI1053P
The HI1053P is a glass body, refillable, double junction pH electrode with a BNC and pin connector. The pin connector is used to enable the CAL Check function of the HI2221, HI2222, and HI2223 benchtop meters.
This electrode has a triple ceramic junction in the outer reference cell and the conical pH sensing portion is made with low temperature glass. This design consideration is ideal for emulsions, fats and creams, soil and semi-solid samples, low conductivity solutions, and for measuring samples at cooler temperatures.
• Triple Ceramic Junction
• Double Junction Design
• Refillable Electrode
pH Electrode with Micro Bulb and BNC + Pin Connector - HI1083P
The HI1083P is a glass body, single reference junction micro pH electrode with a BNC and pin connector. The pin connector is used to enable the CAL Check function of the HI2221, HI2222, and HI2223 benchtop meters. This electrode features a bulb tip that is only 3 mm in diameter and can be used to measure pH in samples as little as 100 µL.
This probe is ideal for 96 well plates and for expensive samples that offer little volume to work with. The HI1083P has a unique open junction design in which there is a viscolene (hard gel) electrolyte layer that is free of silver chloride (AgCl) between the sample to be measured and the internal reference cell.
• Open Junction
• Micro Bulb Tip
• Viscolene Gel Electrolyte
Gel Filled pH Electrode with Quick Connect DIN Connector - HI11103
The HI11103 is a glass body, gel filled, single junction pH electrode that has a built-in temperature sensor and connects to the meter with a quick connect DIN connector. This type of connector is proprietary to specific meters such as the HI98190.
This electrode has a single ceramic junction in the outer reference cell and the spherical pH sensing portion is made with general purpose glass. This design consideration is ideal for the laboratory that does not want to refill a pH electrode.
• Built-In Temperature Sensor
• Single Junction Design
• Gel Filled
Digital Glass Body pH Electrode with Matching Pin for General Purpose - HI11311
The HI11311 is a glass body, refillable, double junction pH electrode with a matching pin and a built-in temperature sensor for temperature compensated measurements in a single probe design. This probe connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes.
The matching pin integrated into the HI11311 is for the Sensor Check™ capability of the edge pH meter; this feature is used to identify problems with the pH electrode such as cracks in the sensing glass or poor condition of the reference junction.
The HI11311 electrode features a built-in microchip that stores sensor type, serial number, and calibration information. It also features a single ceramic junction and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for general purpose laboratory use.
• Matching Pin for enabling Sensor Check feature that alerts to a broken electrode or clogged junction
• Double Junction Reference
• 3.5 mm Connector
Refillable Glass Body pH Electrode with Quick Connect DIN Connector - HI11313
The HI11313 is a glass body, refillable, double junction pH electrode that has a built-in temperature sensor and connects to the meter with a quick connect DIN connector. This type of connector is proprietary to specific meters such as the HI98190.
This electrode has a single ceramic junction in the outer reference cell and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for general purpose use.
• Refillable Electrode
• Double Junction Design
• High Temperature (HT) Glass
Refillable Combination pH Electrode with BNC + Pin Connector - HI1131P
The HI1131P is a glass body, refillable, double junction pH electrode with a BNC and pin connector. The pin connector is used to enable the CAL Check function of the HI2221, HI2222, and HI2223 benchtop meters.
This electrode has a single ceramic junction in the outer reference cell and the spherical pH sensing portion is made with high temperature glass. This design consideration is ideal for laboratory samples, liquid samples, and high temperature samples, as well as general purpose use.
• Refillable Electrode
• Double Junction Design
• High Temperature (HT) Glass
Digital PEI Body pH Electrode with Matching Pin for Field Applications - HI12301
The HI12301 is a plastic body, double junction, gel filled pH electrode with a matching pin and built-in temperature sensor for temperature compensated measurements in a single probe design. This probe connects to the meter with a 3.5 mm connector. The 3.5 mm connector is proprietary to meters that use digital electrodes.
The matching pin integrated into the HI12301 is for the Sensor Check™ capability of the edge pH meter; this feature is used to identify problems with the pH electrode such as cracks in the sensing glass or poor condition of the reference junction.
The HI12301 electrode features a built-in microchip that stores sensor type, serial number, and calibration information. It also features a single ceramic junction and the spherical pH sensing portion is made with low temperature glass. The electrode has a rugged PEI (polyetherimide) body that has the chemical resistance of a glass body in an unbreakable plastic making it ideal for field and industrial applications.
• Matching Pin for enabling Sensor Check feature that alerts to a broken electrode or clogged junction
• Double Junction Reference
• 3.5 mm Connector
Gel Filled PEI Body pH Electrode with Quick Connect DIN Connector - HI12303
The HI12303 is a Polyetherimide (PEI) body, double junction pH electrode with a built-in temperature sensor and connects to the meter that has a Quick Connect DIN connector. This type of connector is proprietary to specific meters such as the HI98190.
The HI12303 pH electrode has a single ceramic junction in the outer reference cell and the spherical pH sensing portion is made with low temperature glass and is protected by the fins of the durable PEI body. This design consideration excels in measurements with portable meters due to the durability and that the probe does not require maintenance other than cleaning and calibration.
• Chemically-Resistant PEI Body
• Double Junction Reference
• Low Temperature (LT) Glass
Spare pH Electrode - HI1270
The HI1270 is the replacement pH electrode for the previous model of the HI98103 Checker pH meter. Replacing the pH electrode is both quick and easy. Simply unscrew the old probe to be replaced and screw on the new one.
Spare Checker pH Electrode - HI1271
The HI1271 is the spare pH electrode for the HI98100, HI98103, and HI98115 Checker pH meters. Replacing the pH electrode is both quick and easy. Simply unscrew the old probe to be replaced and screw on the new one.
Economy PEI Plastic Body pH Electrode - HI1286
The HI1286 brings the ability to test pH to any user at an affordable price. The polyetherimide (PEI) body protects against accidental breakage while the spherical glass tip is perfect for aqueous samples due to the large surface area. Suitable for samples from 0 to 80℃ (32 to 176℉), this electrode is perfect for any general use application.
• PEI body offers increased durability
• PTFE junction protects against clogging
• Universal BNC connector makes this the perfect replacement electrode
pH Electrode for Direct Soil Measurement - HI12923
The HI12923 is a glass body, refillable, single junction pH electrode with a quick connect DIN connector. This electrode has a triple ceramic junction in the outer reference cell and the conic pH sensing tip is made with low temperature glass. There is an integrated amplifier and built-in temperature sensor for automatically temperature compensated pH readings.
The design consideration for the HI12923 is ideal for pH measurements in soils and soil slurries. The HI12923 is designed for use with Hanna’s HI99121 portable pH meter.
• Triple Ceramic Junction
• Low Temperature Glass
• Built-in Temperature Sensor
pH Electrode for Direct Soil Measurement - HI1292D
The HI1292D is a glass body, refillable, single junction pH electrode with a DIN connector. This electrode has a triple ceramic junction in the outer reference cell and the conic pH sensing tip is made with low temperature glass. There is an integrated amplifier and built-in temperature sensor for automatically temperature compensated pH readings.
The design consideration for the HI1292D is ideal for pH measurements in soils and soil slurries. The HI1292D is designed for use with Hanna's HI99121 portable pH meter.