Electrodes & Probes

HI76407 Polarographic Dissolved Oxygen Probe with 20m cable

The HI76407 is a standard polarographic dissolved oxygen probe for Hanna's benchtop and portable dissolved oxygen meters. It contains a platinum cathode and silver anode and is for use with HI76407A/P PTFE membrane caps. The probe's tapered design makes it ideal for BOD measurements.

• Polarographic Sensor

• Tapered

• Integrated Temperature Sensor

HI76407 Polarographic Dissolved Oxygen Probe with 10m cable

The HI76407 is a standard polarographic dissolved oxygen probe for Hanna's benchtop and portable dissolved oxygen meters. It contains a platinum cathode and silver anode and is for use with HI76407A/P PTFE membrane caps. The probe's tapered design makes it ideal for BOD measurements.

• Polarographic Sensor

• Tapered

• Integrated Temperature Sensor

Spare Dissolved Oxygen Screw Cap Membranes - HI76407A/P HI76407A/P

Spare Dissolved Oxygen Screw Cap Membranes - HI76407A/P

The HI76407A/P are spare dissolved oxygen screwcap membranes designed especially for Hanna's portable polarographic dissolved oxygen probes. The caps are constructed of durable ABS plastic with polytetrafluoroethylene (PTFE) oxygen permeable membranes. Each cap is easily filled with electrolyte and installed on the probe.

• Pre-tensioned PTFE Membranes

• Screw Cap Design

Spare Dissolved Oxygen Screw Cap Membranes For Galvanic Sensors - HI76409A/P HI76409A/P

Spare Dissolved Oxygen Screw Cap Membranes For Galvanic Sensors - HI76409A/P

The HI76409A/P are spare dissolved oxygen screwcap membranes designed especially for Hanna's portable galvanic dissolved oxygen probes and sensors. The caps are constructed of durable ABS plastic with high density polyethylene (HDPE) oxygen permeable membranes. Each cap is easily filled with electrolyte and installed on the probe.

• Screw Cap Design

• Pre-tensioned Membranes

Transparent Protective Cap for DO Probes - HI740211 HI740211

Transparent Protective Cap for DO Probes - HI740211

The HI740211 is a transparent protective cap for D.O. probes to prevent scratches or damage due to the oxygen permeable membrane.

Polarographic Dissolved Oxygen Probe with Protective Sleeve - HI764073 HI764073

Polarographic Dissolved Oxygen Probe with Protective Sleeve - HI764073

The HI764073 is a spare polarographic dissolved oxygen probe for use with the HI98193 portable dissolved oxygen meter. Perfect for both lab and field applications, this probe comes with a protective sleeve to endure any environment. Calibration is quick and measurements are temperature compensated. The sensitive PTFE membrane can be changed in seconds making it ideal for use in the field. 

• Polarographic Sensor

• Protective Sleeve

• Integrated Temperature Sensor

Thin Polarographic Dissolved Oxygen Probe for HI2400 - HI76408 HI76408

Thin Polarographic Dissolved Oxygen Probe for HI2400 - HI76408

The HI76408 is a thinner polarographic dissolved oxygen probe for Hanna’s benchtop and portable dissolved oxygen meters. It contains a platinum cathode and silver anode and is for use with HI76407A/P PTFE membrane caps. The probe’s thin design makes it ideal for wine packaging measurements.

• Polarographic Sensor

• Thin Design

• Integrated Temperature Sensor

® Compatible Digital DO/Temperature Electrode - HI764080 HI764080

® Compatible Digital DO/Temperature Electrode - HI764080

The HI 764080 is a digital dissolved oxygen electrode with built-in temperature sensor. This ultra-thin, Clark-type polarographic electrode is designed for measuring DO in aqueous solutions and contains a built-in microchip that stores sensor type, serial number, and calibration information. The sensor features a platinum cathode with a silver/silver chloride anode, an integrated temperature sensor, and easily replaceable PTFE membrane caps. The HI 764080 is designed for use with Hanna’s edge® pH/EC/DO meter.

• Digital Probe

• Ultra-Thin Body

• Integrated Temperature Sensor

• 3.5mm Connector

Thin Polarographic Dissolved Oxygen Probe for BOD Test - HI76408W HI76408W

Thin Polarographic Dissolved Oxygen Probe for BOD Test - HI76408W

The HI76408W is a thin polarographic dissolved oxygen probe for Hanna’s portable dissolved oxygen meters designed to be used when performing a BOD test. Calibration is fast and simple, and measurements are temperature compensated. The sensitive PTFE membrane can be changed in a few seconds for continued use in the field.

• Specially Designed for BOD Tests

• Clark-type Polarographic Sensor

• Integrated Temperature Sensor

Protective Sleeve for HI76409 Probe Series - HI76409-0 HI76409-0

Protective Sleeve for HI76409 Probe Series - HI76409-0

The HI76409-0 is a protective sleeve for HI76409 galvanic probe series. This sleeve will help protect the probe from damage making it ideal for use in rugged or demanding environments.

Digital Galvanic Dissolved Oxygen Probe for HI98199 – HI764103 HI764103

Digital Galvanic Dissolved Oxygen Probe for HI98199 – HI764103

The HI764103 is a digital dissolved oxygen probe with a built-in temperature sensor. This galvanic probe contains a built-in microchip that stores sensor type, serial number, and calibration information that is automatically detected by the HI98199 portable meter. The sensor features a silver cathode with a zinc anode, an integrated temperature sensor, and easily replaceable HDPE membrane caps.

• Digital Probe

• Galvanic Technology

• Replaceable pre-tensioned HDPE Membrane

4m (13') HI764113

4m (13')

The HI764113 is the replacement probe for use with HI98198 Optical Dissolved Oxygen Meter

opdo™ Probe Replacement Cap Kit - HI764113-1 HI764113-1

opdo™ Probe Replacement Cap Kit - HI764113-1

The HI764113-1 is a replacement cap kit for use with HI764113 Optical Dissolved Oxygen Probe for the HI98198 Optical Dissolved Oxygen Meter.

• RFID tag is embedded into the Smart Cap sensor

• Stores factory calibration coefficients

• Monitor the time from the first use in order to alert when to replace

Calibration / Storage Vessel for HI764113 opdo Probe – HI764113-2 HI764113-2

Calibration / Storage Vessel for HI764113 opdo Probe – HI764113-2

The HI764113-2 is a calibration and storage vessel for use with HI764113 Optical Dissolved Oxygen Probe. Calibrating the HI764113 Optical Dissolved Oxygen Probe requires placing the probe in a calibration solution of 0% oxygen. After use the HI764113 should be properly stored to ensure the maximum lifetime of the probe.

• Correct storage can extend the life of the probe.

Optical Dissolved Oxygen Probe – HI764113 HI7641133

Optical Dissolved Oxygen Probe – HI764113

The HI764113 is the replacement probe for the HI98198 Optical Dissolved Oxygen Meter.