Titration Reagents & Standards

Pump Calibration Standard for Sulfur Dioxide Mini Titrator - HI84500-55 HI84500-55

Pump Calibration Standard for Sulfur Dioxide Mini Titrator - HI84500-55

The HI84500-55 is a 120 mL bottle of pump calibration standard that is used to calibrate the dosing system of the HI84500 Sulfur Dioxide Mini Titrator for Wine Analysis.

A calibrated dosing pump allows for the accurate determination of the amount of titrant used when performing a titration. The amount of volume dosed along with the concentration of the titrant is used by the pre-programmed formula within the HI84500 in determining the exact concentration of sulfur dioxide. The pump calibration procedure should be performed anytime the titrant or ORP electrode is replaced.

• Standardized solution

• Clearly marked expiration date and lot number

• Air tight bottle with tamper-proof seal

Acid Reagent for Free and Total Sulfur Dioxide - HI84500-60 HI84500-60

Acid Reagent for Free and Total Sulfur Dioxide - HI84500-60

The HI84500-60 is a 230 mL bottle of acid reagent required for both low and high range determinations of sulfur dioxide in wine using the HI84500 Sulfur Dioxide Mini Titrator for Wine Analysis.

The acid reagent is used to lower the pH value of the sample prior to performing a titration. With 5 mL of reagent required per test, there is enough acid reagent for approximately 46 tests.

• Pre-measured solution

• Clearly marked expiration date and lot number

• Air tight bottle with tamper-proof seal

Alkaline Reagent for Total Sulfur Dioxide - HI84500-61 HI84500-61

Alkaline Reagent for Total Sulfur Dioxide - HI84500-61

The HI84500-61 is a 120 mL bottle of alkaline reagent required for determination of total sulfur dioxide in wine using the HI84500 Sulfur Dioxide Mini Titrator for Wine Analysis.

This alkaline reagent is used to raise the pH value of the sample prior to performing a total sulfur dioxide titration. With 5 mL of reagent required per total SO2 test, there is enough alkaline reagent for approximate 24 tests.

• Pre-measured solution

• Clearly marked expiration date and lot number

• Air tight bottle with tamper-proof seal

Stabilizer Powder Packets for Sulfur Dioxide Mini Titrator (100 Packets) - HI84500-62 HI84500-62

Stabilizer Powder Packets for Sulfur Dioxide Mini Titrator (100 Packets) - HI84500-62

The HI84500-62 are packets of stabilizer reagent required for determination of sulfur dioxide in wine using the HI84500 Sulfur Dioxide Mini Titrator for Wine Analysis.

The HI84500 mini titrator uses two different titrant solutions that contain different concentrations of potassium iodate to measure a wide range of sulfur dioxide concentration in wine. Both low and high range measurements require the addition of HI84500-62 stabilizer powder to convert iodate into iodine, which in turn reacts with sulfur dioxide. The HI84500-62 powder is packaged into single use packets that are emptied into the sample prior to performing the titration.

• Pre-measured packets

• Clearly marked expiration date and lot number

Titrant for Titratable Acidity in Wine Mini Titrator - HI84502-50 HI84502-50

Titrant for Titratable Acidity in Wine Mini Titrator - HI84502-50

The HI84502-50 is a 230 mL bottle of titrant solution for use with the HI84502 TItratable Acidity Mini Titrator for Wine Analysis.

The HI84502-50 titrant solution is used for both the low and high acidity ranges. The titrant is pre-standardized, eliminating the need for any volumetric glassware or a analytical balance and ensuring titrations are fast, accurate, and simple to perform.

Pre-standardized titrant

Clearly marked expiration date and lot number

Air tight bottle with tamper-proof seal

Pump Calibration Standard for Titratable Acidity in Wine Mini Titrator - HI84502-55 HI84502-55

Pump Calibration Standard for Titratable Acidity in Wine Mini Titrator - HI84502-55

The HI84502-55 is a 120 mL bottle of pump calibration standard that is used to calibrate the dosing system of the HI84502 TItratable Acidity Mini Titrator for Wine Analysis. With 4 mL of solution required per pump calibration, there is enough standard to perform approximately 30 pump calibrations.

A calibrated dosing pump allows for the accurate determination of the amount of titrant used when performing a titration. The amount of volume dosed along with the concentration of the titrant is used by the pre-programmed formula within the HI84502 in determining the exact titratable acidity. The pump calibration procedure should be performed anytime the titrant or pH electrode is replaced. Routine calibration is recommended to ensure the highest of accuracy when performing a titration.

• Pre-measured solution

• Clearly marked expiration date and lot number

• Air tight bottle with tamper-proof seal

Low Range Titrant for Titratable Acidity in Fruit Juice Mini Titrator - HI84532-50 HI84532-50

Low Range Titrant for Titratable Acidity in Fruit Juice Mini Titrator - HI84532-50

The HI84532 Titratable Acidity Mini Titrator for Fruit Juice Analysis utilizes two different titrant solutions to cover the entire measurement range of acidity in juices.

The HI84532-50 is a 120 mL bottle of low range titrant with an expected range between 0.10 to 2.00% as citric acid, 0.11 to 2.35% as tartaric acid, and 0.10 to 2.09% as malic acid. The titrant solution is pre-standardized, making titrations fast, accurate, and easy to perform.

• Pre-standardized titrant

• Clearly marked expiration date and lot number

• Air tight bottle with tamper-proof seal