Calibration Solutions
Turbidity Calibration Standards - HI98703-11
The HI98703-11 Turbidity Calibration Standards provide a simple solution to calibrating and validating turbidity meters that have a 0 to 1000 NTU range. Hanna turbidity calibration standards are prepared from NIST traceable primary standard reference materials and come supplied with a certificate of analysis. The certificate of analysis provides the lot number, reference values, and expiration date for traceability when certifying the appropriate turbidity meter.
• Supplied with Certificate of Analysis
• AMCO AEPA-1 primary turbidity standards
• Reusable with long shelf life stability
HI70630L Grease and Fats Acid Cleaning Solution (500 mL)
The HI70630L is an effective acidic cleaning solution that is specially formulated for use in applications where a pH electrode can be coated with grease and fats. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement and stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and prevent any clogging of the junction.
Hanna’s line of cleaning solutions have been specially formulated to have an expiration of 5 years from the date of manufacture.
• Specially formulated cleaning solution to remove meat grease and fats from a pH electrode
• Air tight bottle with tamper-proof seal to ensure quality
• Expiration date and lot number clearly marked on the bottle
HI70631L Grease and Fats Alkaline Cleaning Solution (500 mL)
The HI70631L is an effective alkaline cleaning solution that is specially formulated for use in applications where a pH electrode can be coated with grease and fats. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement and stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and prevent any clogging of the junction.
Hanna’s line of cleaning solutions have been specially formulated to have an expiration of 5 years from the date of manufacture.
• Specially formulated cleaning solution to remove grease and fats from a pH electrode
• Air tight bottle with tamper-proof seal to ensure quality
• Expiration date and lot number clearly marked on the bottle
HI70670L Cleaning Solution for Salt Deposits (500 mL)
The HI70670L is an effective, acidic cleaning solution that is specially formulated for use in industrial applications that permit electrodes to come into contact with salts. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement and stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and prevent any clogging of the junction.
Hanna’s line of cleaning solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
• Specially formulated cleaning solution to remove salt deposits from a pH electrode
• Air tight bottle with tamper-proof seal to ensure quality
• Expiration date and lot number clearly marked on the bottle
HI70635L Cleaning Solution for Wine Deposits (500 mL)
The HI70635L is a highly effective cleaning solution that is specially formulated for use with pH electrodes that become coated with wine juice and must deposits. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement and stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and prevent any clogging of the junction. Measuring the pH in wine is a critical step ensuring the quality of the final product, for more information read our ebook.
Hanna’s line of cleaning solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
• Specially formulated cleaning solution to remove wine deposits from a pH electrode
• Air tight bottle with tamper-proof seal to ensure quality
• Expiration date and lot number clearly marked on the bottle
HI70636L Cleaning Solution for Wine Stains (500 mL)
The HI70636L is a highly effective cleaning solution that is specially formulated for use with pH electrodes that become stained by wine juice or must. Electrodes can become stained from use and can produce inaccurate results even. Hanna’s cleaning solution for wine stains will remove residues that are left on electrode surfaces. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and prevent any clogging of the junction.
Hanna’s line of cleaning solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
• Specially formulated cleaning solution to remove wine stains from a pH electrode
• Air tight bottle with tamper-proof seal to ensure quality
• Expiration date and lot number clearly marked on the bottle
HI7061M General Purpose Cleaning Solution (230 mL)
HI7061M is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction.
• Specially formulated for cleaning electrodes
• Air tight seal to ensure quality
• Expiration date and lot number
HI70060M pH 6.00 Calibration Solution (230 mL)
HI70060M is a premium quality pH 6.0 calibration solution. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna’s line of calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
• Color coded label for easy pH buffer value identification
• Accuracy of ±0.01 pH @ 25℃
• Temperature chart of the actual pH value at various temperatures printed on each sachet
Pool Line General Purpose Cleaning Solution (20 mL x 25 Sachets) - HI7006014P
HI7006014P Pool Line General Purpose Cleaning Solution is a highly effective solution that is formulated for cleaning pH and ORP probes. Electrodes can become coated with a variety of substances when used in swimming pools, hot tubs, and spas. If the probes are not cleaned then inaccurate results can occur. Hanna's cleaning solutions eliminate impurities and residues that are left on electrode surfaces. Hanna suggests cleaning the pH and ORP probes on a regular basis to ensure that the sensor is always clean and the junction free flowing.
• 25 sachets each containing 20 mL of solution
• Convenient packaging for one time use
• Ideal for infrequent use
General Purpose Cleaning Solution (25 x 20 mL) - HI700601P
HI70061P is a general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction.
• Specially formulated for cleaning electrodes
• Packaged with 25 single use sachets
• Expiration date and lot number
HI700630P Grease and Fats Acid Cleaning Solution (25 x 20 mL Sachets)
The HI700630P is an effective acidic cleaning solution that is specially formulated for use in applications were a pH electrode can be coated with grease and fats. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement and stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and prevent any clogging of the junction.
Each sachet has the lot number and expiration date stamped on it and is made of light block foil ensuring freshness each time one is opened. Hanna’s line of cleaning solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened sachet.
• Specially formulated acidic cleaning solution to remove grease and fats from a pH electrode
• Convenient, one-time use sachets ensure freshness of solution
HI70664L Cleaning Solution for Humus Deposits (500 mL)
The HI70664Lis an effective, alkaline cleaning solution that is specially formulated for cleaning pH electrodes used in agricultural applications with humus organic soil matter. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement and stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and prevent any clogging of the junction.
Hanna’s line of cleaning solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
• Specially formulated cleaning solution to remove humus deposits from a pH electrode
• Air tight bottle with tamper-proof seal to ensure quality
• Expiration date and lot number clearly marked on the bottle
HI700635P Cleaning Solution for Wine Deposits (25 x 20 mL Sachets)
The HI700635P is a highly effective cleaning solution that is specially formulated for use with pH electrodes that become coated with wine juice and must deposits. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement and stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and prevent any clogging of the junction.
Each sachet has the lot number and expiration date stamped on it and is made of light block foil ensuring freshness each time one is opened. Hanna’s line of cleaning solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened sachet.
• Specially formulated cleaning solution to remove wine deposits from a pH electrode
• Convenient, one-time use sachets ensure freshness of solution
HI700636P Cleaning Solution for Wine Stains (25 x 20 mL Sachets)
The HI700636P is a highly effective cleaning solution that is specially formulated for use with pH electrodes that become stained by wine juice or must. Electrodes can become stained from use and can produce inaccurate results even. Hanna’s cleaning solution for wine stains will remove residues that are left on electrode surfaces. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and prevent any clogging of the junction.
Each sachet has the lot number and expiration date stamped on it and is made of light block foil ensuring freshness each time one is opened. Hanna’s line of cleaning solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened sachet.
• Specially formulated cleaning solution to remove wine deposits from a pH electrode
• Convenient, one-time use sachets ensure freshness of solution
HI700640P Cleaning Solution for Milk Deposits (25 x 20 mL Sachets)
The HI700640P is a highly effective cleaning solution that is specially formulated for use with pH electrodes that become coated with milk deposits. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement and stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and prevent any clogging of the junction.
Each sachet has the lot number and expiration date stamped on it and is made of light block foil ensuring freshness each time one is opened. Hanna’s line of cleaning solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened sachet.